Ariston Microtec 23 MFFI T2 LLS 23 TT2 Fume Extractor Fime GR00715P Ref. 999397

Ariston Microtec 23 MFFI T2 LLS 23 TT2 Fume Extractor Fime GR00715P Ref. 999397

50 €VAT includedIn stock · 5 units

Extractor: refurbished spare part that evacuates combustion gases with forced draft. Useful if it doesn't start due to draft failure, makes noise, or doesn't rotate. Compatible with Microtec 23 MFFI, Microtec 23 MFFI GPL, Modula 23 MFFI (ref. 999397). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
999397
Brand
Ariston
Type of part
Extractors
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 999397) equips these models. Verified compatibility; check the reference before purchasing.

Microtec

  • Microtec 23 MFFI
  • Microtec 23 MFFI LPG

Modula

  • Modula 23 MFFI

Microgenus

  • Microgenus 23 MFFI

T2

  • T2 23 MFFI

TX

  • TX 23 MFFI

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
A 41Fan faultThe flue gas extractor does not start or is not detected by the electronics (no rotation or no signal), causing the boiler to lock out. Check for 230 V supply at the connector, continuity and free rotation of the fan, and that the air pressure switch closes upon start-up.
E 23Baja velocidad del ventiladorThe extractor is rotating below the expected threshold and is not generating sufficient flow/velocity, causing a safety shutdown. Check the fan's rpm/signal, consumption, and mechanical friction, and confirm that it reaches the nominal speed and activates the pressure switch.
How do I know if this extractor/fan is the one for my boiler?
Verify the reference 999397 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Fime part.
What is it used for?
The extractor/fan evacuates the combustion gases (forced draught).
Does it not start due to a draught fault, make noise, or not spin?
Seized, noisy, or unpowered fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the connector, the 230 V power supply, and free rotation.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler Microtec 23 MFFI T2 LLS 23 TT2 Fime GR00715P