Junkers Euromaxx ZWC 24 MF2A 23 Fime Extractor Ref. 87167711010

Junkers Euromaxx ZWC 24 MF2A 23 Fime Extractor Ref. 87167711010

70 €VAT includedIn stock · 3 units

Extractor: refurbished spare part that evacuates combustion gases with forced draft. Useful if it doesn't start due to draft failure, makes noise, or doesn't spin. Compatible with ZWC24-1MFA23, ZWC24-1MFA31, ZWC24-1MF2A23 (ref. 87167711010). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
87167711010
Brand
Junkers
Type of part
Extractors
Available units
3 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 87167711010) equips these models. Verified compatibility; check the reference before purchasing.

Junkers Euromaxx ZWC 24

  • ZWC24-1MFA23
  • ZWC24-1MFA31
  • ZWC24-1MF2A23
  • ZWC24-1MF2A31

Junkers Euromaxx ZC 24

  • ZC24-1MFA23
  • ZC24-1MFA31

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
C7No fan speed signal.The extractor (Fime fan) does not rotate or does not deliver the tachometric signal to the Heatronic; check the power supply to the motor and the presence of rpm pulses at its connector, as well as the fan's integrated wiring/sensor.
C6The pressure switch does not close.If the extractor does not generate sufficient depression/draught, the air pressure switch does not switch; check that the fan starts and moves flow, measure depression with a manometer and inspect the tubes to the pressure switch and the fan/wiring itself.
C1The pressure switch has activated during operation.Drop in flow/draft due to low revolutions or intermittent extractor fault causes the pressure switch to open during operation; verify fan rpm/consumption and speed signal, and check pressure in the pressure switch while operating.
CATurbine revolutions too high.Anomaly in the extractor control or erroneous reading of its tachometric signal; check the speed sensor/fan wiring and ensure the measured rpm (service menu or tachometer) do not exceed the specified range.
How do I know if this extractor/fan is the one for my boiler?
Verify the reference 87167711010 printed and ensure your model is on the list of compatibles; also compare the connections with the original part. It is a FIME part.
What is it used for?
The extractor/fan evacuates the combustion gases (forced draught).
Does it not start due to a draught fault, make noise, or not spin?
Seized, noisy, or unpowered fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the connector, the 230 V power supply, and free rotation.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.