Junkers Fan Control PCB Auxiliary ZWR2 4 2ADE23 Ref. 87483000300

Junkers Fan Control PCB Auxiliary ZWR2 4 2ADE23 Ref. 87483000300

45 €VAT includedIn stock · 1 unit

Extractor: reconditioned spare part that evacuates combustion gases with forced draft. Useful if it doesn't start due to draft failure, makes noise, or doesn't spin. Reference 87483000300. Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
87483000300
Brand
Junkers
Type of part
Extractors
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
C1Fan speed is not reached.The fan control PCB (Gebläsesteuerung, ref. 87483000300) may not properly excite/regulate the motor, preventing it from reaching the speed; check by measuring the output from the PCB to the fan and ensure that the pressure switch closes with the airflow.
C6Differential pressure signal not detected.Fault in the fan control board causes the fan not to start or not to generate the required flow, and the differential pressure does not close; check voltage/commands from the board to the fan and rule out fan/wiring before replacing the board.
C7Device does not detect a running fan.If the auxiliary fan control board does not supply or read the tacho signal from the fan, the boiler does not detect rotation; check for the presence of speed signal (tacho/Hall) at the connector to the board and ensure the fan is rotating correctly.