Junkers Fan Extractor Euroline ZW23 AE23 G2K108AA13-10 Ref. 87072040010

Junkers Fan Extractor Euroline ZW23 AE23 G2K108AA13-10 Ref. 87072040010

50 €VAT includedIn stock · 1 unit

Extractor: refurbished spare part that evacuates combustion gases with forced draft. Useful if it doesn't start due to draft failure, makes noise, or doesn't spin. Compatible with ZW 23 AE, ZW23AE23, ZW23AE31 (ref. 87072040010). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
87072040010
Brand
Junkers
Type of part
Extractors
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 87072040010) equips these models. Verified compatibility; check the reference before purchasing.

Euroline (ZW 23 AE)

  • ZW 23 AE
  • ZW23AE23
  • ZW23AE31

ZW 20 AME

  • ZW 20-1 AME
  • ZW20-1AME23
  • ZW20-1AME31
  • ZW20-2AME23
  • ZW20-2AME31
  • ZW20AME23
  • ZW20AME31

WR 250 (water heater)

  • WR 250-1 AM1
  • WR 250-3 AM1
  • WR 250-5 AM1

WR 325 (water heater)

  • WR 325-1 AM1
  • WR 325-3 AM1
  • WR 325-5 AM1

ZS 23 AE

  • ZS23AE23
  • ZS23AE31

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
C6The fan is not working.The extractor is blocked/faulty or does not start, it does not generate depression and the control does not detect flow; check the start-up, voltage/power supply, and free rotation of the fan and the closure of the flue pressure switch.
C7Fan problem (fan not working).No tachometric/speed signal from the fan or it is not rotating; check power supply to the fan, tachometer signal/wiring, and replace the extractor if there is no signal.
C1Airflow stopped during operation.The extractor stops or does not maintain RPM, the depression drops, and the control cuts off; check that the fan rotates continuously and that the pressure switch closes during demand.
The reset button flashes once every 4 s (0.25 Hz), and the 90 °C indicator light also flashes (Euroline/ZW 23 AE).Other types of fault: differential pressure switch / air ducts.If the fan does not generate depression, the pressure switch does not close and this warning occurs; check the start and rotation of the extractor, the pressure switch hoses, and its switching.
How do I know if this extractor/fan is the one for my boiler?
Verify the reference 87072040010 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is an EBM part.
What is it used for?
The extractor/fan evacuates the combustion gases (forced draught).
Does it not start due to a draught fault, make noise, or not spin?
Seized, noisy, or unpowered fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the connector, the 230 V power supply, and free rotation.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.