Junkers Fan Extractor Eurosmart ZWA 24 1 AM Fime C25X0G14/20 Ref. 87161432010

Junkers Fan Extractor Eurosmart ZWA 24 1 AM Fime C25X0G14/20 Ref. 87161432010

55 €VAT includedIn stock · 2 units

Extractor: reconditioned spare part that evacuates combustion gases with forced draft. Useful if it doesn't start due to draft failure, makes noise, or doesn't spin. Compatible with ZWA 24-1 A, ZWA 24-1 AM, ZWA 24-1 AI (ref. 87161432010). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
87161432010
Brand
Junkers
Type of part
Extractors
Available units
2 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 87161432010) equips these models. Verified compatibility; check the reference before purchasing.

Junkers Eurosmart ZWA 24-1

  • ZWA 24-1 A
  • ZWA 24-1 AM
  • ZWA 24-1 AI
  • ZWA 24-1 AB
  • ZWA241A

Junkers Ceraclass ZWA/ZW 24

  • Ceraclass Smart ZWA 24-2/3 AI
  • Ceraclass Smart ZWA 24-2/3 AB
  • ZW 24 Ceraclass

Buderus Logamax U052

  • U052-24
  • U052-24K
  • U052-28
  • U052-28K

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
C1The airflow stopped during operation (fan speed too low).The fan does not rotate or loses rpm and the flow rate drops, causing the boiler to detect an air stop; check the power supply voltage to the fan and that it delivers a tachometer signal, as well as verify that the pressure switch activates upon start-up.
C6Ventilation/fan problem: the unit does not detect correct flow (pressure switch does not close or fan out of range, depending on version).If the fan does not start or rotates out of range, the air pressure switch does not close and the boiler locks out; check that the fan receives voltage and rotates freely, measure its speed/pressure, and confirm the closure of the pressure switch with the fan running.
C7No fan speed signal (fan tachometry fault or its wiring).The fan or its internal sensor do not send speed impulses to the PCB; check the continuity of the wiring and measure the tach output of the motor (or replace the fan if it does not generate a signal).
How do I know if this extractor/fan is the one for my boiler?
Verify the reference 87161432010 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a FIME part.
What is it used for?
The extractor/fan evacuates the combustion gases (forced draught).
Does it not start due to a draught fault, make noise, or not spin?
Seized, noisy, or unpowered fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the connector, the 230 V power supply, and free rotation.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.