Ariston Gas Valve AS 24 FF NG Ref. 65104254

Ariston Gas Valve AS 24 FF NG Ref. 65104254

45 €VAT includedIn stock · 4 units

Gas valve: reconditioned spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with AS 24 FF, BS 24 FF, BS II 24 FF (ref. 65104254). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
65104254
Brand
Ariston
Type of part
Gas valves
Available units
4 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 65104254) equips these models. Verified compatibility; check the reference before purchasing.

AS / BS / BS II

  • AS 24 FF
  • BS 24 FF
  • BS II 24 FF

Clas / Clas Evo

  • Clas 24 FF
  • Clas Evo 24 FF

Egis / Egis Plus

  • Egis 24 FF
  • Egis Plus 24 FF

Genus / Genus Evo

  • Genus 24 FF
  • Genus Evo 24 FF

Matis

  • Matis 24 FF

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
5 02Flame detected with the gas valve closed.The gas valve remains open or leaks when the PCB commands it to close, so the ionisation continues to detect a flame. Check for a flame signal without voltage on the valve and verify closure/sealing and pressures of the ramp according to the manufacturer's table.
5 01Flame not detected during ignition (ignition lockout).The gas valve does not open or delivers insufficient flow during start-up. Check for voltage presence in coils during the attempt, outlet/offset pressure according to the manual, and if there is voltage without gas flow, replace or adjust the valve.
5 04Flame lift-off during operation.Unstable regulation or modulation of the gas valve causes an unstable flame. Check and adjust the offset and minimum/maximum flow rates of the valve according to the table and perform a combustion analysis to stabilise the mixture.
How do I know if this gas valve is the one for my boiler?
Verify the reference 65104254 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a SIT part.
What is it used for?
The gas valve regulates and modulates the gas flow to the burner.
Ignition faults, does not modulate, or smells of gas?
It could be the gas valve. IMPORTANT: gas handling ONLY by an authorised technician.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Installation and pressure adjustment by authorised technician; mandatory leak check.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler AS 24 FF NG

Scroll to the top