Beretta Mynute Green 28 C S Gas Valve Ref. 20039202

Beretta Mynute Green 28 C S Gas Valve Ref. 20039202

30 €VAT includedIn stock · 1 unit

Gas valve: refurbished spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with Mynute Green 28 C.S.I., Mynute Green C.S.I., Mynute Green R.S.I. (ref. 20039202). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
20039202
Brand
Beretta
Type of part
Gas valves
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 20039202) equips these models. Verified compatibility; check the reference before purchasing.

Mynute Green

  • Mynute Green 28 C.S.I.
  • Mynute Green C.S.I.
  • Mynute Green R.S.I.

Exclusive Green

  • Exclusive Green

Meteo Green

  • Meteo Green

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
A01Flame lockout due to ignition failure (flame not detected).If the gas valve does not open or modulate, gas does not reach the burner and the boiler exhausts the ignition attempts; check the voltage to the valve during the attempt and input/output pressures with a manometer and, if necessary, recalibrate.
A11Parasite flame (flame detected when it shouldn't be).A gas valve that does not close completely may allow gas to pass after shutdown and maintain a residual flame; check the valve's tightness/closure without voltage and the absence of ionisation signal with the gas cut off.
E021Defective gas valve control board.Fault in the control board/driver of the gas valve (relay/PCB output) or its coils prevents correct operation; check the board output to the valve and the resistance/insulation of the coils, and confirm that the valve operates.
How do I know if this gas valve is the one for my boiler?
Verify the reference 20039202 printed and ensure your model is on the list of compatibles; also compare the connections with the original part. It is a SIT part.
What is it used for?
The gas valve regulates and modulates the gas flow to the burner.
Ignition faults, does not modulate, or smells of gas?
It could be the gas valve. IMPORTANT: gas handling ONLY by an authorised technician.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Installation and pressure adjustment by authorised technician; mandatory leak check.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler Mynute Green 28 C S