Ferroli Domi Projet F 24 D Gas Valve Ref. 39841320

Ferroli Domi Projet F 24 D Gas Valve Ref. 39841320

35 €VAT includedIn stock · 4 units

Gas valve: refurbished spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with Divatech D F24, Divatech D C24, Divatech Micro LN F24 D (ref. 39841320). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
39841320
Brand
Ferroli
Type of part
Gas valves
Available units
4 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 39841320) equips these models. Verified compatibility; check the reference before purchasing.

Ferroli Divatech / Domiproject / Domitech / Easytech (Micro LN, D series)

  • Divatech D F24
  • Divatech D C24
  • Divatech Micro LN F24 D
  • Domiproject F24 D
  • Domiproject C24 D
  • Easytech F24 D

Cointra Essential / Ferroli Excellent (rebrand Divatech Micro LN)

  • Cointra Essential D 24 E
  • Ferroli Excellent D Micro LN 24 E

Lamborghini FL / Ninfa / Taura (series D)

  • FL 24 MCA
  • FL 24 MCS
  • Ninfa D 24
  • Taura D 24 MCA

Joannes Ciprea / Clizia (series D)

  • Ciprea D 24
  • Clizia D 24

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
A01The burner does not ignite.The gas valve does not open/modulate during ignition, gas does not pass, and it does not ionise. Check for 24 VDC at the valve terminals during the attempt, coil resistance (~24–65 Ω), and downstream pressure with a manometer.
A09Gas valve anomaly.The control board detects an electrical fault in the valve circuit (interrupted wiring or faulty valve). Check the continuity of the wiring, coil resistance, and that the valve operates by applying 24 VDC.
A16Gas valve anomaly.Lockout due to valve or its wiring fault: the PCB does not recognise the valve/modulation. Check continuity of the harness, 24 VDC to the modureg, and valve opening; replace if unresponsive.
F50Gas valve anomaly.Fault in the modulating actuator (modureg) or the valve itself. Check the modureg cable, presence of 24 VDC, and valve response; if there is voltage and it does not modulate/open, the valve is damaged.
How do I know if this gas valve is the one for my boiler?
Verify the reference 39841320 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Bertelli & Partners (B&P) SGV100 C1100009 part.
What is it used for?
The gas valve regulates and modulates the gas flow to the burner.
Ignition faults, does not modulate, or smells of gas?
It could be the gas valve. IMPORTANT: gas handling ONLY by an authorised technician.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Installation and pressure adjustment by authorised technician; mandatory leak check.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.