Gas Inlet Valve Chaffoteaux Elexia Comfort 24 FF NAT Ref. 61303533

Gas Inlet Valve Chaffoteaux Elexia Comfort 24 FF NAT Ref. 61303533

15 €VAT includedIn stock · 5 units

Gas valve: refurbished spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Reference 61303533. Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
61303533
Brand
Chaffoteaux
Type of part
Gas valves
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
70-80Safety position due to ignition failure (Elexia Comfort CF/FF with LED bar).If the gas inlet valve (ref. 61303533) is closed, seized, or not opening, gas will not reach the burner and the boiler will enter ignition lockout; check that the handle is aligned with the pipe and confirm gas supply/pressure at the inlet connection.
5 01Flame absence (ignition/ionisation failed).A closed or faulty gas inlet valve prevents gas from reaching the block/burner, the flame does not ionize, and the boiler displays 5 01; confirm the valve is open and check the inlet pressure with a manometer, and bleed the gas if necessary.
501Flame absence (equivalent to 5 01 in many models).If the gas inlet valve is closed/faulty or there is no supply, the burner does not receive gas and the boiler confirms the absence of a flame; check the valve is open, the presence of gas in the property, and inlet pressures.
E01Lockout due to ignition fault / flame not detected (Pigma/Urbia family and similar).A gas inlet valve that does not open or is closed prevents supply to the burner and causes ignition fault E01; check that the gas valve is open and that there is pressure/supply at the boiler inlet.