Gas Mechanism G20 Saunier Duval Gas Valve Isofast C 35 E1 Ref. 05742800

Gas Mechanism G20 Saunier Duval Gas Valve Isofast C 35 E1 Ref. 05742800

45 €VAT includedIn stock · 5 units

Gas valve: reconditioned spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with Isofast C 24 E V1, Isofast C 28 E1, Isofast C 28 E1 Nox (ref. 05742800). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
05742800
Brand
Saunier Duval
Type of part
Gas valves
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 05742800) equips these models. Verified compatibility; check the reference before purchasing.

Isofast

  • Isofast C 24 E V1
  • Isofast C 28 E1
  • Isofast C 28 E1 NOx
  • Isofast C 35 E1
  • Isofast F 28 E1
  • Isofast F 35 E1

Isomax

  • Isomax C 28 E2
  • Isomax F 28 E2

Isotwin

  • Isotwin C 24 E
  • Isotwin C 24 EA
  • Isotwin C 24 EV
  • Isotwin C 24 EV A
  • Isotwin F 24 E
  • Isotwin F 24 E1
  • Isotwin F 24 EA

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.26Fault: gas valve not functioning.The stepper motor of the gas mechanism (valve ref. 05742800) is not operating or is disconnected. Check coil continuity and signal from the PCB; during demand, verify with a manometer that there is no pressure variation at the valve outlet.
F.27Safety shutdown: incorrect flame detection.Non-sealed gas solenoid valve or one that does not close properly produces an incoherent flame signal. Check the valve's tightness (leaks) and ensure the flame extinguishes upon closing; replace the valve if it does not seal.
F.28Start-up fault: ignition failed.The gas valve does not open or is misadjusted, preventing supply to the burner. Check that it receives command/voltage and coil continuity; measure inlet/outlet pressures during the ignition attempt.
F.61Gas valve activation fault.Short circuit to ground in the harness or valve coils, or driver fault in the PCB prevents the valve from activating. Check insulation to ground, coil resistance, and control signal from the electronics.
F.62Gas valve fault: disconnection delay.The valve closes late or does not seal (leaks), allowing gas to pass after the stop command. Check for the closing 'click', immediate drop in ionisation, and absence of gas/flame; perform a tightness test and replace if it does not close in time.
How do I know if this gas valve is the one for my boiler?
Verify the reference 05742800 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The gas valve regulates and modulates the gas flow to the burner.
Ignition faults, does not modulate, or smells of gas?
It could be the gas valve. IMPORTANT: gas handling ONLY by an authorised technician.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Installation and pressure adjustment by authorised technician; mandatory leak check.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.