| F.26 | Fault: gas valve not functioning. | The stepper motor of the gas mechanism (valve ref. 05742800) is not operating or is disconnected. Check coil continuity and signal from the PCB; during demand, verify with a manometer that there is no pressure variation at the valve outlet. |
| F.27 | Safety shutdown: incorrect flame detection. | Non-sealed gas solenoid valve or one that does not close properly produces an incoherent flame signal. Check the valve's tightness (leaks) and ensure the flame extinguishes upon closing; replace the valve if it does not seal. |
| F.28 | Start-up fault: ignition failed. | The gas valve does not open or is misadjusted, preventing supply to the burner. Check that it receives command/voltage and coil continuity; measure inlet/outlet pressures during the ignition attempt. |
| F.61 | Gas valve activation fault. | Short circuit to ground in the harness or valve coils, or driver fault in the PCB prevents the valve from activating. Check insulation to ground, coil resistance, and control signal from the electronics. |
| F.62 | Gas valve fault: disconnection delay. | The valve closes late or does not seal (leaks), allowing gas to pass after the stop command. Check for the closing 'click', immediate drop in ionisation, and absence of gas/flame; perform a tightness test and replace if it does not close in time. |