Gas Valve Hermann Saunier Duval Micraplus Condens 25A Ref. 0020195511

Gas Valve Hermann Saunier Duval Micraplus Condens 25A Ref. 0020195511

45 €VAT includedIn stock · 1 unit

Gas valve: refurbished spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with Micraplus Condens 25A, Semia Condens 25A, Semia Condens 30A (ref. 0020195511). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
0020195511
Brand
Hermann
Type of part
Gas valves
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 0020195511) equips these models. Verified compatibility; check the reference before purchasing.

Micraplus Condens

  • Micraplus Condens 25A

Semia Condens

  • Semia Condens 25A
  • Semia Condens 30A

Thelia Condens

  • Thelia Condens 25A

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.61Fault: gas valve control.The electronics detect an electrical fault in the activation/supervision of the valve (coils shorted to ground or wiring). Check coil resistances, absence of leakages, and control voltage from the PCB; if not compliant, replace the valve.
F.62Error: gas valve disconnection controller.Delayed or non-tight closure of the valve detected (gas flow despite closure command). Check that the valve closes without delay and is tight: inspect ionisation after shutdown and perform a tightness/manometer test; replace if not tight.
F.88Fault: gas valve.The gas valve is not/poorly connected or has a short circuit in its harness. Check the multi-connector, wiring continuity, and coils; if the wiring is OK and the fault persists, replace the valve.
F.28Fault: unsuccessful ignition on start-up.Among the possible causes is 'error in the gas valve', which prevents the correct opening/closing of the gas supply. Check connection pressure at the gas valve itself, opening signal from the PCB, and valve response (program P.01 and manometer).
F.27Safety shutdown: flame detection error (simulation).A non-sealed solenoid/gas valve may allow gas to pass with the burner off and generate an implausible flame signal. Check the valve's tightness after closing (without ionisation current or leakage) using a leak test/manometer; replace if there is passage.
How do I know if this gas valve is the one for my boiler?
Verify the reference 0020195511 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The gas valve regulates and modulates the gas flow to the burner.
Ignition faults, does not modulate, or smells of gas?
It could be the gas valve. IMPORTANT: gas handling ONLY by an authorised technician.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Installation and pressure adjustment by authorised technician; mandatory leak check.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler Saunier Duval Micraplus Condens 25A

Scroll to the top