Saunier Duval Themafast NOx F 30 B 2 Gas Valve Ref. 0020124874

Saunier Duval Themafast NOx F 30 B 2 Gas Valve Ref. 0020124874

75 €VAT includedIn stock · 1 unit

Gas valve: reconditioned spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with Semia Tek F 24, Semia Tek C 24, Semia F 24 (ref. 0020124874). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
0020124874
Brand
Saunier Duval
Type of part
Gas valves
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 0020124874) equips these models. Verified compatibility; check the reference before purchasing.

Semia / Semia Tek

  • Semia Tek F 24
  • Semia Tek C 24
  • Semia F 24
  • Semia C 24

Isotwin

  • Isotwin C 25 E
  • Isotwin C 30 E
  • Isotwin F 25 E
  • Isotwin F 30 E
  • Isotwin F 30 H

Isomax

  • Isomax C 30
  • Isomax F 35 H

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.26Fault: gas valve not functioning.The stepper motor/actuator of the valve is not connected or the valve assembly is faulty, so it does not open/close. Check by measuring the signal to the modulator, continuity/insulation of coils, and power supply from the PCB.
F.61Fault: control/activation of the gas valve.Short circuit to ground in the harness towards the valve or coils in short prevent its activation. Check coil resistance, leaks to ground, and continuity/wiring between the PCB and valve.
F.62Gas valve fault: disconnection delay/not sealed.The valve does not close in time or does not seal (leaks), leaving gas when it should not. Check tightness and closing times; soap/manometer test and control signal without the presence of a flame.
F.27Safety shutdown: incorrect flame detection (flame simulation).The sealed gas solenoid valve allows gas to pass when it shouldn't, simulating a flame. Verify with a tightness test and ensure there is no opening signal with ionization reading present.
F.28Start-up fault: ignition failed.Incorrect/faulty or improperly regulated gas valve prevents gas supply to the burner. Check pressure before/after the valve, correct type, and signal/modulation; adjust or replace the valve.
F1Ignition fault (lockout).In Semia/Semia Tek ranges, the gas valve that does not open or is improperly adjusted prevents ignition. Check the supply and ensure the valve opens (manometer on test point, voltage/signal to the actuator) and adjust/replace.
How do I know if this gas valve is the one for my boiler?
Verify the reference 0020124874 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Crouzet piece.
What is it used for?
The gas valve regulates and modulates the gas flow to the burner.
Ignition faults, does not modulate, or smells of gas?
It could be the gas valve. IMPORTANT: gas handling ONLY by an authorised technician.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Installation and pressure adjustment by authorised technician; mandatory leak check.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.