Saunier Duval Themafast Condens F 24 Valve Ref. 0020018436

Saunier Duval Themafast Condens F 24 Valve Ref. 0020018436

40 €VAT includedIn stock · 5 units

Gas valve: refurbished spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with Themafast Condens F30, Themafast Condens F30E, Themafast Condens F24E (ref. 0020018436). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
0020018436
Brand
Saunier Duval
Type of part
Gas valves
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 0020018436) equips these models. Verified compatibility; check the reference before purchasing.

Themafast Condens

  • Themafast Condens F30
  • Themafast Condens F30E
  • Themafast Condens F24E

Thema Condens

  • Thema Condens F24E

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.26Fault: gas valve not functioning.The stepper motor/coils of the valve do not operate or are disconnected, so it does not open/modulate. Check the continuity of the coils, connector, and harness up to the PCB and ensure it receives voltage in test P.0.
F.27Safety shutdown: incorrect flame detection.The sealed gas solenoid valve may allow gas to pass when it should be closed, causing an implausible flame signal. Check the valve's tightness/closure and absence of flame with the gas cut off.
F.28Start-up fault: ignition failed.Among the causes is an incorrect/faulty gas valve that does not open or supply flow. Check inlet pressure, that the valve is the correct reference, activation signal, and pressure/output during the ignition attempt.
F.56Fault in the regulation of the circulating flow sensor.The manual associates this fault with a faulty gas valve or its wiring harness, so a defective valve may cause incorrect flow/mix reading/regulation. Check the valve and wiring; if it reappears after adjustment, replace the valve.
F.61Gas valve control fault.The PCB detects that it cannot activate the valve (coils grounded/cut). Check insulation and resistance of coils, continuity of the harness, and control output from the electronics.
F.62Gas valve fault. Disconnection delay.The valve sticks or leaks and takes time to close after the flame extinguishes. Check that the flame signal drops when the gas is cut and the valve's tightness/quick closure; replace if there is a delay/leak.
How do I know if this gas valve is the one for my boiler?
Verify the reference 0020018436 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The gas valve regulates and modulates the gas flow to the burner.
Ignition faults, does not modulate, or smells of gas?
It could be the gas valve. IMPORTANT: gas handling ONLY by an authorised technician.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Installation and pressure adjustment by authorised technician; mandatory leak check.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler Themafast Condens F 24

Scroll to the top