PCB Baxi Roca Laura 30/30 - Ref. 122420630

PCB Baxi Roca Laura 30/30 - Ref. 122420630

Stock · 1 unit

When you turn on the hot water tap or activate the heating, the Baxi Roca Laura 30/30 PCB is responsible for controlling the ignition, the modulation of the burner, the pump, and the safety features of the boiler. If this part fails, it is possible that the boiler will not start, become locked, or operate erratically. It is compatible with several models from the Baxi Roca Laura 30 range, such as the Laura 30 A G.N., Laura 30/30 G.P., and others. It is recommended to replace it when these symptoms occur to restore the normal operation of your system.

VAT included

Compatibility

Baxi Roca boilers compatible with reference 122420630

PCB with reference 122420630. 16 verified compatibilities: LAURA 30 A G.N. and LAURA 30 A G.P..

Proven compatibility

Boiler modelFamilyVerification
Baxi Roca LAURA 30 A G.N.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30 A G.P.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30 AF G.N.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30 AF G.P.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30/30 G.N.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30/30 G.P.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30/30 F G.N.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30/30 F G.P.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 35 A G.N.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35 A G.P.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35 AF G.N.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35 AF G.P.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35/35 G.N.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35/35 G.P.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35/35 F G.N.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35/35 F G.P.Baxi Roca Laura 35Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 122420630 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 122420630. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 122420630 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler shows no signs of life, neither indicators nor display.

    Cause: The power supply stage of the PCB or its internal fuse has failed and the electronics are left without voltage.

    Before changing the PCB, check with a multimeter that there is mains voltage at its input terminals.

  • 02

    Lockouts or fault codes appear that are not related to any specific component of the boiler.

    Cause: The PCB mismanages the readings from the sensors and locks the boiler due to a misinterpretation, not because of an actual fault in them.

    Note the exact code and the moment it appears, and discard NTC, pressure switch, and flame detection electrode.

  • 03

    The pump or the gas valve does not activate even though the PCB appears to be on.

    Cause: An internal relay on the PCB that does not close the contact prevents current from reaching those components even though the rest of the electronics are functioning.

    With the boiler calling for heat, listen for the click of the relay activating before assuming the pump or the gas valve is faulty.

  • 04

    The boiler turns on but goes through short cycles, stopping and starting again repeatedly.

    Cause: The PCB intermittently loses the signal from a safety sensor and cuts off the gas supply as a precaution.

    Check if the cuts coincide with vibrations or with the heating of the boiler, and verify that the connectors on the PCB are properly fitted.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Baxi Roca PCB 122420630

Catalogue reference
122420630
Brand
Baxi Roca
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturing batch
10X74AL LF
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 122420630

What is the code 'LOT 10X74AL LF' that appears on the label of the PCB?
It is a manufacturing batch marking, not a component reference.
Is this PCB suitable for a Baxi Roca Laura 35/35 F?
Yes, the Laura 35/35 F is on the list of compatible boilers, along with Laura 30, 30/30, 35, and 35/35.

Spare parts related to Baxi Roca Laura 30

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
PCB Baxi Roca Laura 30/30 - Ref. 122420630