PCB Baxi Roca Laura 30/30 Ref. 4202802

PCB Baxi Roca Laura 30/30 Ref. 4202802

Stock · 1 unit

The Baxi Roca Laura 30 boilers use the Baxi Roca Laura 30/30 PCB Ref. 4202802, which acts as the brain of the boiler, controlling the ignition, burner modulation, pump, and safety features. If it has faults, you will notice that the boiler does not start, gets locked, or operates erratically. This PCB is compatible with several models from the Laura 30 and 35 range, such as LAURA 30 A G.N., LAURA 30/30 F G.P., among others. It is recommended to replace it when these symptoms are evident, ensuring proper performance of the boiler.

VAT included

Compatibility

Baxi Roca boilers compatible with reference 122420630

PCB with reference 122420630. 16 verified compatibilities: LAURA 30 A G.N. and LAURA 30 A G.P..

Proven compatibility

Boiler modelFamilyVerification
Baxi Roca LAURA 30 A G.N.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30 A G.P.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30 AF G.N.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30 AF G.P.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30/30 G.N.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30/30 G.P.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30/30 F G.N.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30/30 F G.P.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 35 A G.N.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35 A G.P.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35 AF G.N.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35 AF G.P.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35/35 G.N.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35/35 G.P.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35/35 F G.N.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35/35 F G.P.Baxi Roca Laura 35Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 122420630 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 122420630. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 122420630 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and there are no indicators lit on the panel.

    Cause: The 1.25 A fuse that protects the transformer on the PCB may have blown, cutting off power to the electronics.

    With the boiler unplugged, check the continuity of the fuse before replacing the complete PCB.

  • 02

    The pump or the burner does not start even though the thermostat is calling for heat.

    Cause: The NAIS relays on the PCB do not switch and do not send the ignition command to those elements.

    Listen for the click of the relays when the demand is activated; its absence is a clear indication before changing the PCB.

  • 03

    The boiler turns off by itself after a few minutes of operation.

    Cause: It may be due to a relay intermittently losing contact due to wear or overheating.

    Check if the cut coincides with the moment when the pump or the burner should activate, to narrow down which relay is faulty.

  • 04

    The boiler does not respond to any controls or indicators, although it has power.

    Cause: The MYRRA transformer that powers the control electronics may have a damaged winding.

    Measure with a multimeter if there is voltage in the secondary of the transformer before replacing the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Baxi Roca PCB 122420630

Catalogue reference
122420630
Brand
Baxi Roca
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Transformer fuse (F2)
1.25 A
Transformer
MYRRA, EN 60950
Relays
NAIS, 10 A 250 V~
Manufacturer of the relays
NAIS (Matsushita/Panasonic Electric Works)
PCB / batch code
LAURA 30/30 · LOT 35733 · 4202802
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 122420630

Does this PCB work for my Baxi Roca Laura 30/30?
Yes, it is compatible with Laura 30, 30/30, 30/30 F, and 35.
And for a Baxi Roca Laura 35?
Yes, the Laura 35 is also on the list of compatible boilers in this document.
What fuse does the transformer of this Baxi Roca PCB Laura use?
A 1.25 A fuse, according to the label on the PCB itself.
What transformer and relays does this PCB have?
A MYRRA transformer (EN 60950) and NAIS relays rated at 10 A to 250 V~.

Spare parts related to Baxi Roca Laura 30

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model