PCB Baxi Roca Laura 30/30 Ref. 4202802

PCB Baxi Roca Laura 30/30 Ref. 4202802

The Baxi Roca Laura 30 boilers use the Roca Laura 30/30 PCB Ref. 4202802, which acts as the brain of the boiler, controlling the ignition, burner modulation, pump, and safety features. If it has faults, you will notice that the boiler does not start, locks out, or operates erratically. This PCB is compatible with several models from the Laura 30 and 35 range, such as LAURA 30 A G.N., LAURA 30/30 F G.P., among others. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms are evident, ensuring the correct performance of the boiler.

Catalogue reference
122420630
Warranty
1 year
VAT included OUT OF STOCK
Compatibility

Baxi Roca boilers compatible with reference 122420630

PCB with reference 122420630. 16 verified compatibilities: LAURA 30 A G.N. and LAURA 30 A G.P..

Proven compatibility

Boiler modelFamilyVerification
Baxi Roca LAURA 30 A G.N.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30 A G.P.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30 AF G.N.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30 AF G.P.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30/30 G.N.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30/30 G.P.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30/30 F G.N.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 30/30 F G.P.Baxi Roca Laura 30Contrasted
Baxi Roca LAURA 35 A G.N.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35 A G.P.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35 AF G.N.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35 AF G.P.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35/35 G.N.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35/35 G.P.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35/35 F G.N.Baxi Roca Laura 35Contrasted
Baxi Roca LAURA 35/35 F G.P.Baxi Roca Laura 35Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 122420630 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 122420630. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 122420630

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and there are no indicators lit on the panel.

    Cause: The 1.25 A fuse that protects the transformer on the PCB may have blown, cutting off power to the electronics.

    With the boiler unplugged, check the continuity of the fuse before replacing the complete PCB.

  • 02

    The pump or the burner does not start even though the thermostat is calling for heat.

    Cause: The NAIS relays on the PCB do not switch and do not send the ignition command to those elements.

    Listen for the click of the relays when the demand is activated; its absence is a clear indication before changing the PCB.

  • 03

    The boiler turns off by itself after a few minutes of operation.

    Cause: It may be due to a relay intermittently losing contact due to wear or overheating.

    Check if the cut coincides with the moment when the pump or the burner should activate, to narrow down which relay is faulty.

  • 04

    The boiler does not respond to any controls or indicators, although it has power.

    Cause: The MYRRA transformer that powers the control electronics may have a damaged winding.

    Measure with a multimeter if there is voltage in the secondary of the transformer before replacing the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Baxi Roca PCB 122420630

Catalogue reference
122420630
Uniclima internal SKU
PLRL30
Brand
Baxi Roca
Type of part
PCBs (control boards)
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Transformer fuse (F2)
1.25 A
Transformer
MYRRA, EN 60950
Relays
NAIS, 10 A 250 V~
Manufacturer of the relays
NAIS (Matsushita/Panasonic Electric Works)
PCB / batch code
LAURA 30/30 · LOT 35733 · 4202802
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 122420630

Does this PCB work for my Baxi Roca Laura 30/30?
Yes, it is compatible with Laura 30, 30/30, 30/30 F, and 35.
And for a Baxi Roca Laura 35?
Yes, the Laura 35 is also on the list of compatible boilers in this document.
What fuse does the transformer of this Baxi Roca PCB Laura use?
A 1.25 A fuse, according to the label on the PCB itself.
What transformer and relays does this PCB have?
A MYRRA transformer (EN 60950) and NAIS relays rated at 10 A to 250 V~.

Spare parts related to Baxi Roca Laura 30

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
PCB Baxi Roca Laura 30/30 Ref. 4202802