PCB Baxi Roca Laura 30/30 F - Ref. 122420630
The Baxi Roca Laura 30/30 F PCB is a fundamental component that controls the ignition, burner modulation, pump, and safety features of the boiler. When it malfunctions, the boiler may fail to start, become locked, or operate erratically. This model is compatible with several boilers in the Baxi Roca Laura 30 and 35 range, such as the LAURA 30/30 G.N. and the LAURA 35 A G.P., among others. It is recommended to replace it when the boiler shows ignition problems or instability in its operation.
VAT included
Consult via WhatsAppBaxi Roca boilers compatible with reference 122420630
PCB with reference 122420630. 16 verified compatibilities: LAURA 30 A G.N. and LAURA 30 A G.P..
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca LAURA 30 A G.N. | Baxi Roca Laura 30 | Contrasted |
| Baxi Roca LAURA 30 A G.P. | Baxi Roca Laura 30 | Contrasted |
| Baxi Roca LAURA 30 AF G.N. | Baxi Roca Laura 30 | Contrasted |
| Baxi Roca LAURA 30 AF G.P. | Baxi Roca Laura 30 | Contrasted |
| Baxi Roca LAURA 30/30 G.N. | Baxi Roca Laura 30 | Contrasted |
| Baxi Roca LAURA 30/30 G.P. | Baxi Roca Laura 30 | Contrasted |
| Baxi Roca LAURA 30/30 F G.N. | Baxi Roca Laura 30 | Contrasted |
| Baxi Roca LAURA 30/30 F G.P. | Baxi Roca Laura 30 | Contrasted |
| Baxi Roca LAURA 35 A G.N. | Baxi Roca Laura 35 | Contrasted |
| Baxi Roca LAURA 35 A G.P. | Baxi Roca Laura 35 | Contrasted |
| Baxi Roca LAURA 35 AF G.N. | Baxi Roca Laura 35 | Contrasted |
| Baxi Roca LAURA 35 AF G.P. | Baxi Roca Laura 35 | Contrasted |
| Baxi Roca LAURA 35/35 G.N. | Baxi Roca Laura 35 | Contrasted |
| Baxi Roca LAURA 35/35 G.P. | Baxi Roca Laura 35 | Contrasted |
| Baxi Roca LAURA 35/35 F G.N. | Baxi Roca Laura 35 | Contrasted |
| Baxi Roca LAURA 35/35 F G.P. | Baxi Roca Laura 35 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 122420630 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 122420630. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 122420630 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The display or indicators of the boiler are flashing or showing incoherent information.
Cause: A fault in the control board causes incorrect readings that are directly reflected in the information displayed to the user.
Note what the display shows exactly and when it changes, and check that the connectors of the display itself are properly fitted to the PCB.
- 02
The room thermostat is not able to start the boiler.
Cause: The PCB is the one that receives the command from the thermostat and decides whether to start; if its input circuit fails, the command is lost.
First, check that the thermostat is working with new batteries and that the cable is properly connected to the corresponding terminals on the PCB.
- 03
The boiler locks out with different fault codes without a clear pattern.
Cause: The electronics of the PCB poorly manage the signals from the safety sensors and cause lockouts that do not always correspond to those components.
Record the codes that appear and discard the pressure switch and NTC by checking their continuity with a multimeter.
- 04
The boiler does not ignite at all, with no indicator lights or sound.
Cause: The power supply stage of the PCB, or the fuse that protects it, has stopped delivering current to the electronics.
Check with a multimeter that power is reaching the input of the PCB and visually inspect the condition of the fuse before replacing it.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Baxi Roca PCB 122420630
- Catalogue reference
- 122420630
- Brand
- Baxi Roca
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- current
- 128 A
- voltage
- 450 V
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Baxi Roca LAURA 30 A G.P. manual (PDF)Document © Baxi Roca, provided as a technical reference.