Beretta Arte 24 CSI N PCB Ref. R10023537
Control PCB for Beretta Arte 24 CAI/CSI N and Ciao 24/28 CAI/CSI N boilers. In the center of the board, there is a transformer soldered, manufactured by Idea S.r.l. (Italy). It is replaced when the boiler does not ignite, does not respond to the ignition command, or shows an error associated with the board.
VAT included
Consult via WhatsAppBeretta boilers compatible with reference R10023537
PCB with reference R10023537. Five confirmed compatibilities: Ciao 24 CAI N and Ciao 24 CSI N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta Ciao 24 CAI N | Beretta Ciao N | Contrasted |
| Beretta Ciao 24 CSI N | Beretta Ciao N | Contrasted |
| Beretta Ciao 28 CAI N | Beretta Ciao N | Contrasted |
| Beretta Ciao 28 CSI N | Beretta Ciao N | Contrasted |
| Beretta Arte 24 CSI N | Beretta Arte N | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. R10023537 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference R10023537. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB R10023537 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and there is no reaction when the command is given.
Cause: The PCB controls the thermostat signal and sends it to the burner and the gas valves.
Check if there is power to the boiler and if the room thermostat is calling for heat before replacing the PCB.
- 02
An error code appears on the display associated with the PCB.
Cause: The PCB monitors the safety features of the boiler and displays a code when it detects an anomaly in its circuits.
Note the exact code and check which component is being monitored before replacing the entire PCB: sometimes the fault is with a sensor, not the board.
- 03
Burnt, darkened, or swollen components are visible on the PCB.
Cause: The transformer or other power components on the PCB may fail due to overvoltage or age and leave visible marks.
Inspect the PCB in good light before discarding it: a burn mark confirms the fault more reliably than the symptom alone.
- 04
The boiler stops responding completely, with no display or indicators.
Cause: If the PCB loses its internal power supply or its control electronics fail, no signal reaches any component of the boiler.
Check if there is any visible fuse on the PCB and test it with a multimeter before replacing it completely.
Fault codes for Beretta that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 01 | Lockout due to absence of flame (indicated as solid red LED on Ciao N). | The CP08 control board may fail in managing/delivering ignition/ionization commands or in flame supervision, causing lockout 01; if, after checking electrodes, gas, and wiring, the issue persists, the manual itself indicates replacing the control board. To confirm, measure voltages on the board (e.g., 230 VAC at CN1.2–CN1.3 and ignition checks); if everything is correct and there is no ignition, replace the PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Beretta R10023537 PCB.
- Catalogue reference
- R10023537
- Brand
- Beretta
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Transformer code
- CPBTR08 10030433
- Transformer manufacturer
- Idea S.r.l. (Italy)
- CE marking of the transformer
- 0694BS1516
- Transformer batch
- 1170/31/07/R
- Transformer voltage and frequency
- 210V~, 30-60Hz (TV1,5s T57,5s RE30 N000J)