Beretta PCB (various Models) Gruppo Giordano Ref. R10028890
PCB manufactured by Gruppo Giordano (Giordano Controls), identified by the logo on the label attached to the board and by CE marking with datamatrix code. Valid for numerous models of Beretta boilers from the Ciao, Mynute, Boiler, Rain, Option Boiler, and Super Kompakt series, with reference R10028890, previous code R10022174, and equivalent in Riello boilers with reference 4365239.
VAT included
Consult via WhatsAppBeretta boilers compatible with reference R10028890
PCB with reference R10028890. 25 verified compatibilities: Kompakt 22 CSI and Super Kompakt 24 CAI.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta Kompakt 22 CSI | Beretta Kompakt / Super Kompakt | Contrasted |
| Beretta Super Kompakt 24 CAI | Beretta Kompakt / Super Kompakt | Contrasted |
| Beretta Super Kompakt 24 CSI | Beretta Kompakt / Super Kompakt | Contrasted |
| Beretta Super Kompakt 24 RSI | Beretta Kompakt / Super Kompakt | Contrasted |
| Beretta Ciao 24 CAI N | Beretta Ciao | Contrasted |
| Beretta Ciao 24 CSI N/AR | Beretta Ciao | Contrasted |
| Beretta Ciao 28 CAI N | Beretta Ciao | Contrasted |
| Beretta Ciao 28 CSI N/AR | Beretta Ciao | Contrasted |
| Beretta Mynute 18 CSI AR | Beretta Mynute | Contrasted |
| Beretta Mynute 24 CAI N | Beretta Mynute | Contrasted |
| Beretta Mynute 24 CSI N/AR | Beretta Mynute | Contrasted |
| Beretta Mynute 28 CAI N | Beretta Mynute | Contrasted |
| Beretta Mynute 28 CSI N/AR | Beretta Mynute | Contrasted |
| Beretta Mynute 20/20 | Beretta Mynute | Contrasted |
| Beretta Boiler 24 BAI | Beretta Boiler / Mynute Boiler / Option Boiler | Contrasted |
| Beretta Boiler 24 BSI/AR | Beretta Boiler / Mynute Boiler / Option Boiler | Contrasted |
| Beretta Boiler 28 BAI | Beretta Boiler / Mynute Boiler / Option Boiler | Contrasted |
| Beretta Boiler 28 BSI/AR | Beretta Boiler / Mynute Boiler / Option Boiler | Contrasted |
| Beretta Mynute Boiler 24 BSI | Beretta Boiler / Mynute Boiler / Option Boiler | Contrasted |
| Beretta Option Boiler 24 BSI/AR | Beretta Boiler / Mynute Boiler / Option Boiler | Contrasted |
| Beretta Rain 24 CAI | Beretta Rain / Rain Box | Contrasted |
| Beretta Rain 24 CSI/AR | Beretta Rain / Rain Box | Contrasted |
| Beretta Rain 28 CSI/AR | Beretta Rain / Rain Box | Contrasted |
| Beretta Rain Box 24 CSI AR | Beretta Rain / Rain Box | Contrasted |
| Beretta Rain Box 28 CSI/AR | Beretta Rain / Rain Box | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part R10028890 is the one for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference R10028890. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB R10028890 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not turn on, there is no LED or display visible, as if it is not receiving power.
Cause: a fault in the PCB (internal fuse, burnt component or power stage) prevents the unit from operating even though it receives mains voltage
First, check the fuse on the PCB and the input voltage at the power connector before replacing it completely.
- 02
The display or the LEDs show a fault code that does not disappear even after you reset the boiler.
Cause: the control electronics detect a signal out of range (flame, temperature, pressure...) and block the ignition for safety reasons
note the exact code and first check the component it points to (sensor, pressure switch, flame electrode) before assuming that the PCB is faulty
- 03
The room thermostat or the programmer do nothing, the boiler does not respond to the setpoint changes.
Cause: the stage of the PCB that processes the demand signal has stopped reading it correctly
check the wiring and the bridges of the thermostat connector, and try bridging the demand directly on the PCB before replacing it
- 04
The boiler turns on and off by itself intermittently, without the same cause repeating every time.
Cause: Damaged solder joints or degraded components on the PCB cause it to lose stability and cut off the supply erratically.
check for moisture, rust, or loose connectors on the PCB before declaring it faulty
Fault codes for Beretta that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| A01 | ACF module lockout alarm / ACF electronic fault alarm (ignition and flame control). | Fault in the ACF module (ignition and flame control PCB, ref. R10028890) preventing spark generation or ionization reading. Check power supply to the module and presence of spark/ionization feedback; if electrodes and wiring are correct and the issue persists, replace the ACF module. |
| 50-59 | PCB (boiler electronic fault). | In Kompakt/Super Kompakt models with a separate ACF module, a fault in the ACF module (R10028890) or its communication with the main board can trigger the 5x family. Check voltages and connectors between boards; if the error does not disappear after verifications/reset, replace the ignition/flame control board (ACF) or the main board according to diagnosis. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Beretta PCB R10028890
- Catalogue reference
- R10028890
- Brand
- Beretta
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- CE marking
- present, along with 2D datamatrix code
- Manufacturer code (Gruppo Giordano)
- ACF01N1