Beretta Super Exclusive Mix 26 CSI EV PCB - Module Code 10021848
When you open the hot water tap, the Beretta Super Exclusive Mix 26 CSI PCB controls the ignition, burner modulation, and safety functions of your boiler. If this part fails, the boiler may not start, may lock out, or may behave erratically, showing faults such as 05, 51, 53, 54, or 55. This PCB is compatible with several models from the Super Exclusive MIX range and other models from the Beretta brand, such as the Super Exclusive 24 CSI and the Super Exclusive ECO 28 CSI, among others. A technician should confirm through diagnosis whether it needs to be replaced when you notice any symptoms of malfunction.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- Catalogue reference
- R10024558
- Warranty
- 1 year
Beretta boilers compatible with reference R10024558
PCB with reference R10024558. 22 verified compatibilities: Super Exclusive MIX 24 CSI and Super Exclusive MIX 26 CSI.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta Super Exclusive MIX 24 CSI | Super Exclusive MIX | Contrasted |
| Beretta Super Exclusive MIX 26 CSI | Super Exclusive MIX | Contrasted |
| Beretta Super Exclusive MIX 28 CSI | Super Exclusive MIX | Contrasted |
| Beretta Super Exclusive MIX 30 CSI | Super Exclusive MIX | Contrasted |
| Beretta Super Exclusive MIX 32 CSI | Super Exclusive MIX | Contrasted |
| Beretta Super Exclusive 24 CAI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 CAI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 24 CSI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 CSI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 RAI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 RSI | Super Exclusive | Contrasted |
| Beretta Super Exclusive ECO 28 CSI | Super Exclusive ECO | Contrasted |
| Beretta Super Exclusive ECO 32 CSI | Super Exclusive ECO | Contrasted |
| Beretta Super Exclusive ECO MIX 24 CSI | Super Exclusive ECO | Contrasted |
| Beretta Super Exclusive ECO MIX 28 CSI | Super Exclusive ECO | Contrasted |
| Beretta Super Exclusive Micro 28 CAI | Super Exclusive Micro / Micromix | Contrasted |
| Beretta Super Exclusive Micromix 28 CSI | Super Exclusive Micro / Micromix | Contrasted |
| Beretta Super Exclusive Micromix 32 CSI | Super Exclusive Micro / Micromix | Contrasted |
| Beretta Sinthesi 25 CSI | Super Exclusive Sinthesi | Contrasted |
| Beretta Sinthesi 29 CSI | Super Exclusive Sinthesi | Contrasted |
| Beretta Sinthesi 35 CSI | Super Exclusive Sinthesi | Contrasted |
| Beretta Sinthesi MIX 25 CSI | Super Exclusive Sinthesi | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. R10024558 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference R10024558. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB R10024558
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler ignites and heats, but the pump does not start or stops and starts on its own, without you controlling it.
Cause: The relay on this PCB is the one that activates the pump; if it gets stuck or remains open, the pump does not respond.
Listen for a click from the relay when requesting heating; if you don't hear it, check this before replacing the pump.
- 02
The hot water does not have priority: the heating remains hot even when you open the tap.
Cause: The three-way valve depends on the signal from this relay on the PCB; if it fails, the valve does not switch.
Manually move the three-way valve to see if it works properly before blaming the relay.
- 03
There is an attempt to start the pump or valve that is not completed.
Cause: The relay receives the command but does not keep the contact closed long enough.
Make sure that the connection screws of the module are properly tightened and free of rust before replacing the part.
- 04
A fault code for the pump or the gas valve appears, which disappears after resetting, but returns.
Cause: This usually happens when a relay output starts to fail before it completely breaks down.
Note if the fault code always appears when requesting domestic hot water or heating; this helps to determine if the fault is in this relay or in another component.
Beretta fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| 05 | The boiler is not communicating with the remote control panel. | It could be a problem with the control board or the cable that connects to the boiler. Check that the cables are properly connected and that there is power. If everything is correct but it still doesn't work, replace the control board. |
| 51 | Fault in the PCB of the boiler | This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement. |
| 53 | Memory error on the PCB | This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement. |
| 54 | Error in the settings of the PCB. | This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement. |
| 55 | Error in the settings of the PCB (parameters S) | There is an error in the configuration of the S parameters of the PCB. Check and reload these parameters. If the error persists after configuring them, it must be confirmed through diagnosis whether it is necessary to replace the PCB. |
| 59 | Fault in the PCB of the boiler | This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Beretta PCB R10024558
- Catalogue reference
- R10024558
- Uniclima internal SKU
- MEBSEMIX26
- Brand
- Beretta
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Module code (CODE)
- 10021848
- Secondary code / batch
- 37449000 BR0626
- Module model
- ACF02 1.5-7.5 E
- CE marking
- 0085AU0274
Manuals and technical documentation