Auxiliary PCB Beretta Cupra Mix 32 CSI Ref. R10028891
In the Beretta Cupra Mix 32 CSI boilers, the Auxiliary PCB R10028891 from the manufacturer Gruppo Giordano is installed. This control board manages the ignition, burner modulation, pump, and safety features of the boiler. If it fails, the boiler may not start, become locked, or operate erratically, displaying fault code 01: Flame failure. It is compatible with models from the Super Exclusive, Super Exclusive Mix, Eco Mix, and Meteo ranges, among others. It should be replaced when there are ignition failures or unstable behavior.
VAT included
Consult via WhatsAppBeretta boilers compatible with reference R10028891
PCB with reference R10028891. 22 verified compatibilities: Super Exclusive 24 CAI and Super Exclusive 28 CAI.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta Super Exclusive 24 CAI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 CAI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 24 CSI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 CSI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 24 RAI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 RAI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 RSI | Super Exclusive | Contrasted |
| Beretta Super Exclusive Eco Mix 24 CSI | Super Exclusive Mix / Eco Mix / Micromix / Sinthesi | Contrasted |
| Beretta Super Exclusive Eco Mix 28 CSI | Super Exclusive Mix / Eco Mix / Micromix / Sinthesi | Contrasted |
| Beretta Super Exclusive Mix 24 CSI | Super Exclusive Mix / Eco Mix / Micromix / Sinthesi | Contrasted |
| Beretta Super Exclusive Mix 28 CSI | Super Exclusive Mix / Eco Mix / Micromix / Sinthesi | Contrasted |
| Beretta Super Exclusive Mix 32 CSI | Super Exclusive Mix / Eco Mix / Micromix / Sinthesi | Contrasted |
| Beretta Super Exclusive Micro 28 CAI | Super Exclusive Mix / Eco Mix / Micromix / Sinthesi | Contrasted |
| Beretta Super Exclusive Micromix 28 CSI | Super Exclusive Mix / Eco Mix / Micromix / Sinthesi | Contrasted |
| Beretta Super Exclusive Micromix 32 CSI | Super Exclusive Mix / Eco Mix / Micromix / Sinthesi | Contrasted |
| Beretta Super Exclusive Sinthesi 25 CSI | Super Exclusive Mix / Eco Mix / Micromix / Sinthesi | Contrasted |
| Beretta Super Exclusive Sinthesi 29 CSI | Super Exclusive Mix / Eco Mix / Micromix / Sinthesi | Contrasted |
| Beretta Super Exclusive Sinthesi 35 CSI | Super Exclusive Mix / Eco Mix / Micromix / Sinthesi | Contrasted |
| Beretta Meteo 24 CAI | Meteo / Meteo Mix | Contrasted |
| Beretta Meteo 28 CAI | Meteo / Meteo Mix | Contrasted |
| Beretta Meteo Mix 24 CSI | Meteo / Meteo Mix | Contrasted |
| Beretta Meteo Mix 28 CSI | Meteo / Meteo Mix | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. R10028891 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference R10028891. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB R10028891 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler generally works, but a specific component (fan, pump, or three-way valve) stops responding.
Cause: The auxiliary PCB acts as an intermediary between the main PCB and certain components; if it fails, that component does not receive the command even though the rest functions properly.
Measure with a multimeter if current is reaching that component at the moment it should be activated, before replacing the auxiliary.
- 02
The boiler displays a fault code that the manual associates with an internal communication failure.
Cause: The auxiliary PCB sends signals between the main PCB and the peripherals; a fault here can be interpreted as a communication failure.
Check that the connector or flat cable between the two PCBs is properly seated before replacing the auxiliary.
- 03
A specific mode of the boiler (for example, a mixed circuit) is not responding, although the rest is working fine.
Cause: In these models, the auxiliary PCB manages additional functions; if it fails, only that function is lost and not the entire unit.
Check if the fault always occurs in the same specific function before considering the auxiliary as faulty.
- 04
When connecting the boiler, there is a burning smell or a component appears blackened in this area.
Cause: A short circuit or a damaged electronic component in the auxiliary can visibly burn.
With the boiler unplugged, look for burn marks or a localized smell on this PCB before deciding to replace it.
Fault codes for Beretta that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 01 | Flame failure (lockout due to ignition/flame detection). | Fault in the ignition/flame control PCB (ACF module, Ref. R10028891): it does not generate a spark or manage ionisation, causing the "flame control unit lockout". First, check the electrode and wiring; if they are correct, check/power supplies and replace the ignition PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Beretta PCB R10028891
- Catalogue reference
- R10028891
- Brand
- Beretta
- Type of part
- PCBs (control boards)
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- voltage
- 220 V
- capacitor
- 470 µF
- thermal protection
- 100 °C