Beretta Super Exclusive 24 CSI PCB - Ref. 20205196
The Beretta Super Exclusive 24 CSI PCB, with reference 20205196, is a key component that controls the ignition, the pump, and the gas valve in the boiler. When this part fails, the boiler does not start, and the pump or the burner do not receive the necessary commands to operate. It is compatible with models from the Beretta Super Exclusive Ecomix range, such as the Super Exclusive Ecomix 24 CSI and the 28 CSI, among others. It is recommended to replace it when these malfunction symptoms occur to ensure the proper performance of the boiler.
VAT included
Consult via WhatsAppBeretta boilers compatible with reference 20205196
PCB with reference 20205196. Two confirmed compatibilities: Super Exclusive Ecomix 24 CSI and Super Exclusive Ecomix 28 CSI.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta Super Exclusive Ecomix 24 CSI | Beretta Super Exclusive Ecomix | Contrasted |
| Beretta Super Exclusive Ecomix 28 CSI | Beretta Super Exclusive Ecomix | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 20205196 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 20205196. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 20205196 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and the display is off.
Cause: There is no power reaching the PCB, so the boiler does not receive the command to turn on.
Check if there is power to the PCB and verify that the input fuse is not blown before replacing it.
- 02
The pump or the fan is always on or does not start when the boiler needs heat.
Cause: The output relays activate the components; if one fails, that element does not respond to the command.
With the boiler turned off, check if the component is still functioning or if it doesn't start when the demand is forced; this helps to identify the relay before replacing the entire PCB.
- 03
The boiler locks out displaying different fault codes without a clear pattern.
Cause: A damaged connector or a loose contact on the PCB causes incorrect readings that the electronics interpret as sensor faults.
Note the fault codes that appear; if they change without a fixed pattern, it is more likely that the problem is with the PCB and not with a loose sensor.
- 04
The room thermostat does not affect the boiler, which does not start even when heat is requested.
Cause: The PCB translates the thermostat signal into a power-on command; if it fails, the request is not processed.
Bridge the thermostat terminals directly on the PCB; if the boiler starts, the problem is with the thermostat or the wiring, not with the PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Beretta PCB 20205196
- Catalogue reference
- 20205196
- Brand
- Beretta
- Type of part
- PCBs (control boards)
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Relays
- Finder