Beretta Super Exclusive Ecomix 24 CSI PCB Ref. R10024558

Beretta Super Exclusive Ecomix 24 CSI PCB Ref. R10024558

Stock · 1 unit

The Beretta Super Exclusive Ecomix 24 CSI PCB, reference R10024558, is the component responsible for controlling the ignition, burner modulation, pump, and safety features of the boiler. If it malfunctions, the boiler may fail to start, become locked, or operate erratically, displaying fault codes such as 51: PCB ANOMALY. This part is compatible with several models, including the Super Exclusive MIX 24 CSI and the Super Exclusive 28 RAI, among others. It is recommended to replace it when the mentioned symptoms are detected or in case of any anomaly in its operation.

VAT included

Compatibility

Beretta boilers compatible with reference R10024558

PCB with reference R10024558. 22 verified compatibilities: Super Exclusive MIX 24 CSI and Super Exclusive MIX 26 CSI.

Proven compatibility

Boiler modelFamilyVerification
Beretta Super Exclusive MIX 24 CSISuper Exclusive MIXContrasted
Beretta Super Exclusive MIX 26 CSISuper Exclusive MIXContrasted
Beretta Super Exclusive MIX 28 CSISuper Exclusive MIXContrasted
Beretta Super Exclusive MIX 30 CSISuper Exclusive MIXContrasted
Beretta Super Exclusive MIX 32 CSISuper Exclusive MIXContrasted
Beretta Super Exclusive 24 CAISuper ExclusiveContrasted
Beretta Super Exclusive 28 CAISuper ExclusiveContrasted
Beretta Super Exclusive 24 CSISuper ExclusiveContrasted
Beretta Super Exclusive 28 CSISuper ExclusiveContrasted
Beretta Super Exclusive 28 RAISuper ExclusiveContrasted
Beretta Super Exclusive 28 RSISuper ExclusiveContrasted
Beretta Super Exclusive ECO 28 CSISuper Exclusive ECOContrasted
Beretta Super Exclusive ECO 32 CSISuper Exclusive ECOContrasted
Beretta Super Exclusive ECO MIX 24 CSISuper Exclusive ECOContrasted
Beretta Super Exclusive ECO MIX 28 CSISuper Exclusive ECOContrasted
Beretta Super Exclusive Micro 28 CAISuper Exclusive Micro / MicromixContrasted
Beretta Super Exclusive Micromix 28 CSISuper Exclusive Micro / MicromixContrasted
Beretta Super Exclusive Micromix 32 CSISuper Exclusive Micro / MicromixContrasted
Beretta Sinthesi 25 CSISuper Exclusive SinthesiContrasted
Beretta Sinthesi 29 CSISuper Exclusive SinthesiContrasted
Beretta Sinthesi 35 CSISuper Exclusive SinthesiContrasted
Beretta Sinthesi MIX 25 CSISuper Exclusive SinthesiContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. R10024558 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference R10024558. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB R10024558 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The Beretta boiler does not ignite and the panel is completely off.

    Cause: The PCB controls the power supply of the equipment; if it doesn't work, no power reaches anything.

    Check the fuse on the PCB and verify that it is receiving 230V before replacing it.

  • 02

    The boiler displays a fault code that appears and disappears on its own, without any repairs being made.

    Cause: An intermittent fault in the control electronics can cause errors that do not correspond to a broken component.

    Note when the code appears to rule out pressure or voltage drops in the home.

  • 03

    The burner ignites but turns off after a few seconds with a flame lockout.

    Cause: The PCB interprets the ionization signal; if it fails, it cuts off the gas even if the flame is present.

    Clean the ionization electrode and check its cable before replacing the PCB.

  • 04

    The boiler does not respond to any button on the control panel.

    Cause: The PCB manages the user interface; if it fails, the buttons have no effect.

    Make sure that the connector between the control panel and the PCB is properly fitted before replacing the part.

Fault codes for Beretta that this part resolves.

CodeFaultDiagnosis and solution
05Communication anomaly with the remote control panelFault in the interface/display PCB (R10024558) or in its RC communication bus; check wiring and communication voltages, and if the link is not restored with correct wiring, replace the PCB.
51PCB FAULTInternal fault of the main PCB (control/power supply or relay failure); check 230 V and 5/24 V on the PCB and connectors. If peripherals and voltages are OK and the issue persists, replace the PCB.
53EEPROM R&W ANOMALYEEPROM memory corruption/defect of the PCB; try reprogramming parameters from the technical menu. If it reappears or doesn't save, replace the PCB.
54ANOMALY DUE TO INCORRECT PARAMETER SETTINGSIncorrect parameterization on the PCB (typical after replacement or reset); verify and load correct gas/power parameters. If not accepted or lost, defective PCB.
55ANOMALY DUE TO INCORRECT S PARAMETER SETTINGSConfiguration error on the PCB (parameter variant S); check/reload parameter set S. If the error returns after configuration, the PCB is damaged.
59PCB FAULTGeneric fault detected by the control electronics; with peripherals and wiring OK, the cause is the PCB and it must be replaced.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Beretta PCB R10024558

Catalogue reference
R10024558
Brand
Beretta
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Code printed on the PCB
10024558
Hardware version
HW:0.2
Traceability number
20420201179900054
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB R10024558

What hardware version does the R10024558 PCB of the Super Exclusive have?
HW:0.2, according to the marking read on the part's label.
When should the PCB of the Beretta Super Exclusive Ecomix 24 CSI be replaced?
When the boiler's control electronics fail.

Spare parts related to Beretta Super Exclusive

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model