Beretta Super Exclusive Ecomix 24 CSI PCB Ref. R10024558
The Beretta Super Exclusive Ecomix 24 CSI PCB, reference R10024558, is the component responsible for controlling the ignition, burner modulation, pump, and safety features of the boiler. If it malfunctions, the boiler may fail to start, become locked, or operate erratically, displaying fault codes such as 51: PCB ANOMALY. This part is compatible with several models, including the Super Exclusive MIX 24 CSI and the Super Exclusive 28 RAI, among others. It is recommended to replace it when the mentioned symptoms are detected or in case of any anomaly in its operation.
VAT included
Consult via WhatsAppBeretta boilers compatible with reference R10024558
PCB with reference R10024558. 22 verified compatibilities: Super Exclusive MIX 24 CSI and Super Exclusive MIX 26 CSI.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta Super Exclusive MIX 24 CSI | Super Exclusive MIX | Contrasted |
| Beretta Super Exclusive MIX 26 CSI | Super Exclusive MIX | Contrasted |
| Beretta Super Exclusive MIX 28 CSI | Super Exclusive MIX | Contrasted |
| Beretta Super Exclusive MIX 30 CSI | Super Exclusive MIX | Contrasted |
| Beretta Super Exclusive MIX 32 CSI | Super Exclusive MIX | Contrasted |
| Beretta Super Exclusive 24 CAI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 CAI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 24 CSI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 CSI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 RAI | Super Exclusive | Contrasted |
| Beretta Super Exclusive 28 RSI | Super Exclusive | Contrasted |
| Beretta Super Exclusive ECO 28 CSI | Super Exclusive ECO | Contrasted |
| Beretta Super Exclusive ECO 32 CSI | Super Exclusive ECO | Contrasted |
| Beretta Super Exclusive ECO MIX 24 CSI | Super Exclusive ECO | Contrasted |
| Beretta Super Exclusive ECO MIX 28 CSI | Super Exclusive ECO | Contrasted |
| Beretta Super Exclusive Micro 28 CAI | Super Exclusive Micro / Micromix | Contrasted |
| Beretta Super Exclusive Micromix 28 CSI | Super Exclusive Micro / Micromix | Contrasted |
| Beretta Super Exclusive Micromix 32 CSI | Super Exclusive Micro / Micromix | Contrasted |
| Beretta Sinthesi 25 CSI | Super Exclusive Sinthesi | Contrasted |
| Beretta Sinthesi 29 CSI | Super Exclusive Sinthesi | Contrasted |
| Beretta Sinthesi 35 CSI | Super Exclusive Sinthesi | Contrasted |
| Beretta Sinthesi MIX 25 CSI | Super Exclusive Sinthesi | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. R10024558 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference R10024558. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB R10024558 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The Beretta boiler does not ignite and the panel is completely off.
Cause: The PCB controls the power supply of the equipment; if it doesn't work, no power reaches anything.
Check the fuse on the PCB and verify that it is receiving 230V before replacing it.
- 02
The boiler displays a fault code that appears and disappears on its own, without any repairs being made.
Cause: An intermittent fault in the control electronics can cause errors that do not correspond to a broken component.
Note when the code appears to rule out pressure or voltage drops in the home.
- 03
The burner ignites but turns off after a few seconds with a flame lockout.
Cause: The PCB interprets the ionization signal; if it fails, it cuts off the gas even if the flame is present.
Clean the ionization electrode and check its cable before replacing the PCB.
- 04
The boiler does not respond to any button on the control panel.
Cause: The PCB manages the user interface; if it fails, the buttons have no effect.
Make sure that the connector between the control panel and the PCB is properly fitted before replacing the part.
Fault codes for Beretta that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 05 | Communication anomaly with the remote control panel | Fault in the interface/display PCB (R10024558) or in its RC communication bus; check wiring and communication voltages, and if the link is not restored with correct wiring, replace the PCB. |
| 51 | PCB FAULT | Internal fault of the main PCB (control/power supply or relay failure); check 230 V and 5/24 V on the PCB and connectors. If peripherals and voltages are OK and the issue persists, replace the PCB. |
| 53 | EEPROM R&W ANOMALY | EEPROM memory corruption/defect of the PCB; try reprogramming parameters from the technical menu. If it reappears or doesn't save, replace the PCB. |
| 54 | ANOMALY DUE TO INCORRECT PARAMETER SETTINGS | Incorrect parameterization on the PCB (typical after replacement or reset); verify and load correct gas/power parameters. If not accepted or lost, defective PCB. |
| 55 | ANOMALY DUE TO INCORRECT S PARAMETER SETTINGS | Configuration error on the PCB (parameter variant S); check/reload parameter set S. If the error returns after configuration, the PCB is damaged. |
| 59 | PCB FAULT | Generic fault detected by the control electronics; with peripherals and wiring OK, the cause is the PCB and it must be replaced. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Beretta PCB R10024558
- Catalogue reference
- R10024558
- Brand
- Beretta
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Code printed on the PCB
- 10024558
- Hardware version
- HW:0.2
- Traceability number
- 20420201179900054
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Beretta Super Exclusive Eco Mix 24 CSI Manual (PDF)Document © Beretta, provided as a technical reference.