Gruppo Giordano Beretta Silver VGR PCB Ref. 0098234
RefurbishedBerettaPCBs (control boards)Gruppo Giordano

Gruppo Giordano Beretta Silver VGR PCB Ref. 0098234

VAT includedStock · 1 unit

If your boiler does not start, locks out, or exhibits erratic behavior, a technical diagnosis must confirm if you need the PCB Gruppo Giordano Beretta Silver VGR Ref. 0098234. This component from Gruppo Giordano controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, you may experience faults such as E056, which indicates a lack of communication between the microprocessor and the board, or COM, which signals a loss of electronic communication. It is compatible with models from the Beretta Silver VGR range, among others. A technician must confirm through diagnosis if it needs to be replaced upon noticing any of these symptoms.

Compatibility

Beretta boilers compatible with reference 0098234

PCB with reference 0098234. A proven compatibility: Silver VGR.

Proven compatibility

Boiler modelFamilyVerification
Beretta Silver VGRBerettaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0098234 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0098234. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 0098234

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler resets itself from time to time, as if the power had been cut and restored.

    Cause: The power supply of the PCB may be unstable, causing spontaneous restarts without an actual power outage.

    Before replacing the PCB, check that the power outlet and the boiler's power cable do not have a loose connection.

  • 02

    The boiler loses the time and programmed settings every time there is a brief power outage.

    Cause: If the power supply to the PCB is not stable, the memory that stores those parameters may not retain them correctly.

    Note whether the problem always occurs after power outages or also without them: if it happens without external outages, it points more towards the PCB.

  • 03

    The boiler stops responding to the control and needs to be unplugged to work again, and this repeats over time.

    Cause: The PCB manages all the electronic control of the boiler; if it fails, the only way to regain response is to force a manual reset.

    Keep track of how often it occurs: if the fault repeats more frequently, it is a typical pattern of a degrading PCB.

  • 04

    The boiler works fine when cold but fails or locks up after being on for a while.

    Cause: A power supply component that operates at its limit may fail due to overheating, even if it does not show issues when cold.

    Check if the fault always appears after the same operating time, and ensure the boiler has ventilation around it before replacing the PCB.

Beretta fault codes that require diagnosis

CodeFaultTechnical checks
50-59PCB (control board) fault/anomaly.The self-diagnosis associates these codes with PCB faults (damaged components, cold solder joints, fuse or relays). Check voltages 230 V and 5/12 V on the board, continuity of fuses, and if it persists, replace or reprogram the PCB.
COMElectronic communication loss with the boiler PCB (>30 s).This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement.
E056Absence of communication between microprocessor/PCB.Microcontroller or communication circuit fault on the PCB. Check stable power supply, ground, and bus; if the error persists with correct wiring/UI, replace the board.
E052Hardware error outside threshold (electronics self-test).The PCB detects internal parameters out of range (hardware). Confirm voltages and network noise; if it reappears after reset and with correct power supply, replace the control board.
FWERIncompatible firmware version (the boiler continues to operate without display/buttons).Firmware incompatibility between the control board and the interface (common after replacing one of them). Check/update matching versions or install the board with the correct reference/firmware.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Beretta PCB 0098234

Catalogue reference
0098234
Uniclima internal SKU
PLBE011
Brand
Beretta
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

PCB manufacturer
Gruppo Giordano
Manufacturer of the relay (switched-mode power supply)
Panasonic
Frequently Asked Questions

Frequently asked questions about the PCB 0098234

Is the PCB Ref. 0098234 for the Beretta Silver VGR manufactured by Beretta or a third party?
The factory Gruppo Giordano, according to the marking read on the edge of the PCB; is not Beretta.
What relay does the switched-mode power supply of the Silver VGR PCB use?
A Panasonic relay, identifiable by the marking on its orange casing.
When should this PCB for the Beretta Silver VGR be replaced?
The technical diagnosis must confirm that it is necessary to replace it, even when the boiler loses electronic control of its functions.
Is this Gruppo Giordano PCB suitable for a different Beretta boiler other than the Silver VGR?
It is only listed as compatible with the Beretta Silver VGR according to the available data.
Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Gruppo Giordano Beretta Silver VGR PCB Ref. 0098234