Gruppo Giordano Beretta Silver VGR PCB Ref. 0098234
If your boiler does not start, locks up, or exhibits erratic behavior, you may need the Gruppo Giordano Beretta Silver VGR PCB Ref. 0098234. This component from Gruppo Giordano controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, you may experience faults such as E056, which indicates a lack of communication between the microprocessor and the board, or COM, which signals a loss of electronic communication. It is compatible with models from the Beretta Silver VGR range, among others. It is recommended to replace it upon noticing any of these symptoms.
VAT included
Consult via WhatsAppBeretta boilers compatible with reference 0098234
PCB with reference 0098234. A proven compatibility: Silver VGR.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta Silver VGR | Beretta | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 0098234 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 0098234. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 0098234 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler resets itself from time to time, as if the power had been cut and restored.
Cause: The power supply of the PCB may be unstable, causing spontaneous restarts without an actual power outage.
Before replacing the PCB, check that the power outlet and the boiler's power cable do not have a loose connection.
- 02
The boiler loses the time and programmed settings every time there is a brief power outage.
Cause: If the power supply to the PCB is not stable, the memory that stores those parameters may not retain them correctly.
Note whether the problem always occurs after power outages or also without them: if it happens without external outages, it points more towards the PCB.
- 03
The boiler stops responding to the control and needs to be unplugged to work again, and this repeats over time.
Cause: The PCB manages all the electronic control of the boiler; if it fails, the only way to regain response is to force a manual reset.
Keep track of how often it occurs: if the fault repeats more frequently, it is a typical pattern of a degrading PCB.
- 04
The boiler works fine when cold but fails or locks up after being on for a while.
Cause: A power supply component that operates at its limit may fail due to overheating, even if it does not show issues when cold.
Check if the fault always appears after the same operating time, and ensure the boiler has ventilation around it before replacing the PCB.
Fault codes for Beretta that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 50-59 | PCB (control board) fault/anomaly. | The self-diagnosis associates these codes with PCB faults (damaged components, cold solder joints, fuse or relays). Check voltages 230 V and 5/12 V on the board, continuity of fuses, and if it persists, replace or reprogram the PCB. |
| COM | Electronic communication loss with the boiler PCB (>30 s). | The main PCB stops communicating with the panel/interface (bus). Check the wiring/bus, voltages of the PCB and the interface; if communication remains down, the cause is usually the PCB itself and it should be replaced. |
| E056 | Absence of communication between microprocessor/PCB. | Microcontroller or communication circuit fault on the PCB. Check stable power supply, ground, and bus; if the error persists with correct wiring/UI, replace the board. |
| E052 | Hardware error outside threshold (electronics self-test). | The PCB detects internal parameters out of range (hardware). Confirm voltages and network noise; if it reappears after reset and with correct power supply, replace the control board. |
| FWER | Incompatible firmware version (the boiler continues to operate without display/buttons). | Firmware incompatibility between the control board and the interface (common after replacing one of them). Check/update matching versions or install the board with the correct reference/firmware. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Beretta PCB 0098234
- Catalogue reference
- 0098234
- Brand
- Beretta
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- PCB manufacturer
- Gruppo Giordano
- Manufacturer of the relay (switched-mode power supply)
- Panasonic