Beretta Kompakt 22 CSI Ignition Control Flame PCB Ref. R10028890

Beretta Kompakt 22 CSI Ignition Control Flame PCB Ref. R10028890

55 €VAT included

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Compatible with Kompakt 22 CSI, Super Kompakt 24 CAI, Super Kompakt 24 CSI (ref. R10028890). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
R10028890
Brand
Beretta
Type of part
PCBs (control boards)
Available units
0 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. R10028890) equips these models. Verified compatibility; check the reference before purchasing.

Beretta Kompakt / Super Kompakt

  • Kompakt 22 CSI
  • Super Kompakt 24 CAI
  • Super Kompakt 24 CSI
  • Super Kompakt 24 RSI

Beretta Ciao

  • Ciao 24 CAI N
  • Ciao 24 CSI N/AR
  • Ciao 28 CAI N
  • Ciao 28 CSI N/AR

Beretta Mynute

  • Mynute 18 CSI AR
  • Mynute 24 CAI N
  • Mynute 24 CSI N/AR
  • Mynute 28 CAI N
  • Mynute 28 CSI N/AR
  • Mynute 20/20

Beretta Boiler / Mynute Boiler / Option Boiler

  • Boiler 24 BAI
  • Boiler 24 BSI/AR
  • Boiler 28 BAI
  • Boiler 28 BSI/AR
  • Mynute Boiler 24 BSI
  • Option Boiler 24 BSI/AR

Beretta Rain / Rain Box

  • Rain 24 CAI
  • Rain 24 CSI/AR
  • Rain 28 CSI/AR
  • Rain Box 24 CSI AR
  • Rain Box 28 CSI/AR

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
A01ACF module lockout alarm / ACF electronic fault alarm (ignition and flame control).Fault in the ACF module (ignition and flame control PCB, ref. R10028890) preventing spark generation or ionization reading. Check power supply to the module and presence of spark/ionization feedback; if electrodes and wiring are correct and the issue persists, replace the ACF module.
50-59PCB (boiler electronic fault).In Kompakt/Super Kompakt models with a separate ACF module, a fault in the ACF module (R10028890) or its communication with the main board can trigger the 5x family. Check voltages and connectors between boards; if the error does not disappear after verifications/reset, replace the ignition/flame control board (ACF) or the main board according to diagnosis.
How do I know if this PCB is for my boiler?
Verify the reference R10028890 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler Kompakt 22 CSI