Cable Harness Baxi Neobit Condens 24 24F Ref. 7773502

Cable Harness Baxi Neobit Condens 24 24F Ref. 7773502

70 €VAT includedIn stock · 1 unit

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Reference 7773502. Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
7773502
Brand
Baxi
Type of part
PCBs (control boards)
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
E.00 .04Return temperature sensor not connected.A loose/oxidised connector or an open wire in the harness 7773502 causes the return NTC to be 'unseen' by the PCB. Check pin-to-pin continuity of the harness between the sensor and the PCB and the ohmic resistance of the NTC.
E.00 .05Return temperature sensor in short circuit.A chafing or crossing between conductors of the harness 7773502 can close the NTC circuit, and the PCB interprets it as a short circuit. Check the NTC and harness insulation; if the NTC measures correctly, inspect/replace the harness.
E.04 .02Flow temperature sensor not connected.Loss of contact in the NTC flow connector within the harness 7773502 causes 'sensor not connected'. Check continuity of the harness to the PCB and the ohmic reading of the NTC.
E.04 .05Flue gas sensor not connected.If the connector/branch of the flue gas sensor in the harness 7773502 is loose or open, the PCB detects 'flue sensor not connected'. Check continuity of the branch and connection at PCB/sensor.
E.02 .17Permanent lack of communication between the gas valve and the boiler PCB.A faulty contact or cut wire in the harness 7773502 (gas valve branch) prevents communication/commands from the PCB. Check continuity of the branch, connector firmness, and control voltage according to the model's diagram.
H.01 .00Temporary communication failure between the gas valve and the boiler PCB.Vibration or moisture can cause intermittencies in the valve branch within the harness 7773502; the equipment reports temporary communication loss. Check connectors, fastening, and continuity; if it reappears, replace the harness.
Scroll to the top