Chaffoteaux Celtic 18 23 Rsce PCB Ref. 60079932

Chaffoteaux Celtic 18 23 Rsce PCB Ref. 60079932

80 €VAT includedIn stock · 1 unit

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Compatible with Celtic 18/23 RSCE, Celtic 2.20 RSc b, Celtic 2.24 RSc b (ref. 60079932). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
60079932
Brand
Chaffoteaux
Type of part
PCBs (control boards)
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 60079932) equips these models. Verified compatibility; check the reference before purchasing.

Chaffoteaux Celtic RSc b / RSCE (18-23 kW)

  • Celtic 18/23 RSCE
  • Celtic 2.20 RSc b
  • Celtic 2.24 RSc b

Chaffoteaux GM RSc b

  • GM 2-20 RSc b

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
3 02Communication error between the internal electronics (PCB) and other modules/HMI.The main PCB may fail in its communication bus or not supply the correct voltage/ground to the display; check HMI↔PCB wiring, regulated 5 V, and continuity. If everything is correct, the PCB is damaged.
3 03Main PCB fault.Self-diagnosis detects an internal fault in the PCB (micro/EEPROM, relays, power supply); confirm voltages 230 V/24 V/5 V, fuses, and tracks. If after reset and verifications it persists, replace the PCB.
3 05Main PCB fault.Internal fault of the PCB (shorts/moisture/faulty components); check supply and regulations on the board and signs of damage. If the error reappears, the repair involves replacing the PCB.
3 06Main PCB fault.Internal fault of the control electronics; confirm stable 5 V/12 V, relays, and solder joints. If there are no external anomalies, the cause is the PCB itself.
3 07Main PCB fault.Critical anomaly detected in the PCB (e.g., microcontroller or supervision failure); if it persists after reset and verification of voltages/cabling, proceed to replace the PCB.
How do I know if this PCB is for my boiler?
Check the reference 60079932 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Chaffoteaux (Ariston Thermo Group) piece; also marketed under the EQUATION brand.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.