PCB (control board): recambio reacondicionado que gobierna el encendido, la modulación y las seguridades de la caldera. Útil si la caldera no enciende, se bloquea o el cuadro no responde. Compatible con 24 CF, 24 FF, 24 CF (ref. 60000571). Includes a one-year warranty. Delivery time and cost are shown at checkout for the destination country.

1
Consult via WhatsApp
Delivery calculated by destination
1-year warranty
14-day return
Technical support

Key Data

Reference
60000571
Brand
Chaffoteaux
Type of part
PCBs (control boards)
Available units
4 units in stock
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

The same part (ref. 60000571) equips these models. Verified compatibility; check the reference before purchasing.

ELEXIA COMFORT

  • 24 CF
  • 24 FF

CALYDRA COMFORT

  • 24 CF
  • 24 FF
  • 28 CF
  • 28 FF

MAYA

  • 24 CF
  • 24 FF
  • 28 FF

MC2

  • 24 CF
  • 24 FF

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
3 03Main PCB fault.Internal fault of the main PCB (microcontroller/power supply/tracks). Check 230/low-voltage on the board, disconnect peripherals to rule out shorts, and if it persists, replace the PCB ref. 60000571.
3 05Main PCB fault.Anomaly detected by the main PCB electronics. Check 5/12 V power supply, connectors, and continuity; if the fault reappears without external loads, the PCB is faulty.
3 06Main PCB fault.PCB fault (e.g., damaged regulation/logical stage). Confirm there are no shorts in sensors/actuators and measure stable voltages on the board; if it persists, replace the 60000571.
3 07Main PCB fault.Recurrent internal fault of the PCB. After checking wiring and peripherals, if the error returns on startup or after reset, the cause is the main board.
3 09Gas relay fault (on PCB).The gas valve relay integrated into the PCB does not switch/close correctly. Check the ignition control and voltage to the valve during demand; if there is no output despite the command, replace the PCB 60000571.
How do I know if this PCB is for my boiler?
Verify the reference 60000571 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Pieza desmontada de una caldera fuera de servicio, revisada y probada. Incluye 1 año de garantía y 14 días de devolución. Delivery time and cost are shown at checkout for the destination country.

Spare Parts Related Boiler Elexia Comfort 24 CF

Scroll to the top