| A23 | Anomaly in the parameters of the control board. | PCB parameters misconfigured (e.g., after replacing the board or losing calibration); check by entering the service menu and correcting/calibrating the parameters. |
| A24 | Anomaly in the parameters of the control board. | PCB parameters misconfigured; check and reprogram/calibrate from service. If it reappears, inspect the PCB. |
| A61 | ABM03 control board anomaly (internal error). | Internal fault of the ABM03 control unit/PCB; check the grounding and power supply. If not resolved after reset/calibration, replace the PCB. |
| A63 | ABM03 control board anomaly (internal error). | Internal error in the ABM03 PCB/control board; check grounding and, if it persists after reset, replace the board. |
| A65 | ABM03 control board anomaly (internal error). | Internal fault of the ABM03 controller/PCB; check earth and power supply, and if it does not clear, replace the board. |
| F64 | ABM03 control board anomaly (internal error). | Internal fault in the ABM03 PCB/control board; confirm correct grounding and stable power supply. If it persists, replace the PCB. |
| F66 | ABM03 control board anomaly (internal error). | Internal fault of the ABM03 control unit on the PCB; check grounding/electrical noise and, if it persists, replace the board. |