Cointra Supra SP 21 I Ineco Control PCB Ref. 9158641

Cointra Supra SP 21 I Ineco Control PCB Ref. 9158641

105 €VAT includedIn stock · 1 unit

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks out, or the display is unresponsive. Compatible with Supra SP 21 I, Supra SP 21 EI, Supra SP 24 I (ref. 9158641). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
9158641
Brand
Cointra
Type of part
PCBs (control boards)
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 9158641) equips these models. Verified compatibility; check the reference before purchasing.

Cointra Supra SP (range 2001/2003)

  • Supra SP 21 I
  • Supra SP 21 EI
  • Supra SP 24 I
  • Supra SP 27 EI

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
A02Flame signal present with burner off (the electronics detect a flame when there shouldn't be one).The control board is one of the two documented causes of this code (the other is the detection electrode): if the board misinterprets the ionisation signal or its flame detection circuit fails, it triggers A02. Verification: first check the detection electrode and its wiring/connection to the board; if the electrode is correct and clean, the fault is with the board and the board should be replaced (Ref. 9158641).
How do I know if this PCB is for my boiler?
Verify the reference 9158641 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is an Ineco part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.