Ferroli Divatech Micro F32 Main PCB Ref. 39820661

Ferroli Divatech Micro F32 Main PCB Ref. 39820661

70 €VAT included

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Compatible with Divatech C24, Divatech C32, Divatech F24 (ref. 39820661). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
39820661
Brand
Ferroli
Type of part
PCBs (control boards)
Available units
0 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 39820661) equips these models. Verified compatibility; check the reference before purchasing.

Divatech

  • Divatech C24
  • Divatech C32
  • Divatech F24
  • Divatech F32

Divatech Micro

  • Divatech Micro F24
  • Divatech Micro F32
  • Divatech Micro C25/F25

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
A02Flame signal present with burner offThe PCB may falsify the ionisation reading (detection circuit on the board), maintaining a flame signal without combustion. Verify by measuring ionisation current and testing with the electrode/cable disconnected; if it persists, reprogram or replace the board.
F04Anomaly in the parameters of the control boardCorrupted or incorrectly set parameters of the PCB (EEPROM/configuration) after replacement or loss of programming. Verify and reprogram service parameters; if it does not save or reappears, replace the PCB.
F05Anomaly in the parameters of the control boardIncorrect PCB calibration/parameter settings (or data corruption) causing fault diagnosis. Check/adjust model parameters with technical tool/menu; if not corrected or does not accept recording, defective PCB.
F07Anomaly in the parameters of the control boardInconsistent PCB configuration with the equipment or damaged memory. Check and reprogram the manufacturer's Pxx parameters; if the error persists after reprogramming, replace the PCB.
A23Anomaly in the parameters of the control boardIncorrect internal parameters of the PCB (model/gas/curves), usually after a board change or deletion. Reprogram parameters according to the service manual; if it does not stabilize, the PCB is damaged.
A24Anomaly in the parameters of the control boardFault/error in the main board parameterization or memory corruption. Check and re-record factory parameters; if the fault persists, replace the PCB.
How do I know if this PCB is for my boiler?
Verify the reference 39820661 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.