PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks out, or the display is unresponsive. Compatible with F24E, F30E, C24E (ref. 39809822). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
39809822
Brand
Ferroli
Type of part
PCBs (control boards)
Available units
3 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 39809822) equips these models. Verified compatibility; check the reference before purchasing.

New Elite

  • F24E
  • F30E
  • C24E
  • C30E
  • VMC24E

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F10Microprocessor anomaly.The microprocessor of the main PCB locks up or detects an internal error; after cutting and restoring power, if the fault persists, the board itself is the cause. Verify reset and, if it continues, replace/control the PCB.
F22Microprocessor anomaly.Same diagnosis as F10: internal fault of the microcontroller on the PCB. Confirm by attempting a reset; if it persists, the main board is responsible and should be checked/replaced.
F25Software anomaly.The firmware/software of the PCB is in an anomalous state. If the error persists after restarting the equipment, the board itself is the documented cause; verify and, if necessary, replace the PCB.
F36Anomaly in the PCB.The self-diagnosis detects an internal fault in the PCB; with the electrical network correct, the solution indicated by the manufacturer is to replace the main control board.
F8There is no flame after the ignition phase.In addition to gas/ionisation causes, the manual documents "control board anomaly"; if gas, electrodes, and grounding are correct, the control PCB is the probable cause and should be checked/replaced.
How do I know if this PCB is for my boiler?
Verify the reference 39809822 printed and ensure your model is on the list of compatibles; also compare the connections with the original part. It is a Honeywell piece.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.