Ferroli Peisa PCB Ref. 38310783

Ferroli Peisa PCB Ref. 38310783

45 €VAT includedIn stock · 2 units

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Reference 38310783. Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
38310783
Brand
Ferroli
Type of part
PCBs (control boards)
Available units
2 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
A02Flame signal present with burner offThe ionization circuit on the PCB interprets a flame when there is none (noise/current leakage or PCB fault). Check the electrode and wiring; if the signal is correct and the issue persists, check/replace the PCB.
A23Anomaly in the parameters of the control boardInternal parameters of the PCB misconfigured/corrupted (NVRAM). Check and reprogram service parameters; if they are not saved or reappear, replace the PCB.
A24Anomaly in the parameters of the control boardIncorrect PCB configuration/parameter table. Access the technical menu and load the correct values; if the fault persists after reprogramming, the PCB is defective.
A26Anomaly in the parameters of the control boardCorruption/incorrect adjustment of PCB parameters. Reprogram parameters with technical tool/menu; if it does not accept changes, replace the PCB.
F20Anomaly in the parameters of the control boardPCB parameters out of specification. Verify/load factory values; if it reappears after correct loading, probable memory fault of the PCB.
F21Anomaly in the parameters of the control boardMismatch/damage in the PCB parameter settings. Check values and reprogram; if not corrected, replace the board.
F40Anomaly in the parameters of the control boardInternal configuration error of the PCB. Readjust parameters to model specification; if the error returns, defective PCB memory.
F47Anomaly in the parameters of the control boardTable of parameters for the damaged or incompatible PCB. Load correct/update parameters; if it doesn't stabilize, replace the PCB.
A61ABM03 control unit anomaly (internal error)Internal fault of the ABM03 controller integrated in the PCB. Check the grounding and power supply; if it persists, replace the control board/PCB.
A63ABM03 control unit anomaly (internal error)Internal error in the control module on the PCB. Check grounding/electrical noise; if diagnosis recommends, replace the PCB.
F64ABM03 control unit anomaly (internal error)Internal fault of the PCB controller (ABM03). Check earth/power connection; if it persists, replace the PCB/controller.
A65ABM03 control unit anomaly (internal error)Internal error of ABM03 on the PCB. Confirm correct grounding and absence of spikes; if not recovered, replace the PCB.
F66Control board anomaly (internal controller error)Internal fault of the PCB controller (e.g., ABM03/DBM). Check grounding and power supply; if the error persists, replace the PCB/controller.