Junkers PCB ZWE24-2AE23 - Ref. 8748300158
The Junkers ZWE24-2AE23 PCB - Ref. 8748300158 is the component that controls the ignition, burner modulation, pump, and safety features of the boiler. When this part fails, the boiler may not start, become locked, or exhibit erratic behavior, with errors E0 and F0 being indicative. It is compatible with boilers from the ZWE24, ZWE28, ZR18-3, ZR24-3, and ZWR18-3 ranges, among others. It is recommended to replace it if the mentioned symptoms occur or if the associated errors are detected.
VAT included
Consult via WhatsAppJunkers boilers compatible with reference 8748300158
PCB with reference 8748300158. 23 verified compatibilities: ZWE24-1ADE23S28 and ZWE24-1ADE31S28.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Junkers ZWE24-1ADE23S28 | ZWE24 (Eurostar) | Contrasted |
| Junkers ZWE24-1ADE31S28 | ZWE24 (Eurostar) | Contrasted |
| Junkers ZWE24-2ADE23S28 | ZWE24 (Eurostar) | Contrasted |
| Junkers ZWE24-2ADE31S28 | ZWE24 (Eurostar) | Contrasted |
| Junkers ZWE24-2AE23 | ZWE24 (Eurostar) | Contrasted |
| Junkers ZWE24-2AE31 | ZWE24 (Eurostar) | Contrasted |
| Junkers ZWE28-2ADE23S28 | ZWE28 | Contrasted |
| Junkers ZWE28-2AE23 | ZWE28 | Contrasted |
| Junkers ZWE28-ADE23S280 | ZWE28 | Contrasted |
| Junkers ZR18-3KDE23S280 | ZR18-3 | Contrasted |
| Junkers ZR18-3KDE31S280 | ZR18-3 | Contrasted |
| Junkers ZR18-3KE11S2800 | ZR18-3 | Contrasted |
| Junkers ZR24-3KDE23S280 | ZR24-3 | Contrasted |
| Junkers ZR24-3KDE31S280 | ZR24-3 | Contrasted |
| Junkers ZR24-3KE11S2800 | ZR24-3 | Contrasted |
| Junkers ZWR18-3KDE23S28 | ZWR18-3 | Contrasted |
| Junkers ZWR18-3KDE31S28 | ZWR18-3 | Contrasted |
| Junkers ZWR18-3KE11S280 | ZWR18-3 | Contrasted |
| Junkers ZWR24-3KDE23S28 | ZWR24-3 / ZWR24-U3 | Contrasted |
| Junkers ZWR24-3KDE31S28 | ZWR24-3 / ZWR24-U3 | Contrasted |
| Junkers ZWR24-3KE11S280 | ZWR24-3 / ZWR24-U3 | Contrasted |
| Junkers ZWR24-U3ADE23 | ZWR24-3 / ZWR24-U3 | Contrasted |
| Junkers ZWR24-U3ADE31 | ZWR24-3 / ZWR24-U3 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 8748300158 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 8748300158. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 8748300158 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The two-digit display shows a fixed fault code that does not clear when resetting the boiler.
Cause: The microprocessor on the PCB displays any faults it detects during ignition or safety.
Note the exact code and compare it with the fault code table of Junkers/Bosch before assuming that the PCB is damaged.
- 02
The boiler is not responding, and the display does not turn on.
Cause: If the PCB does not power the display and the rest of the circuit, the unit shows no signs of operation.
First, check the fuse of the safety module before replacing the entire PCB.
- 03
The flame is always at maximum, it does not decrease even when the water is hot.
Cause: The modulation depends on the signal that the PCB sends to the gas valve; if this signal fails, the flame remains fixed at maximum power.
Check that the temperature sensor is properly connected; a loose sensor can also keep the flame at maximum.
- 04
The remote control or programmer does not affect the boiler.
Cause: The PCB receives the command from the control and converts it into ignition; if the communication module fails, the command is lost.
Try to directly bridge the thermostat on the PCB to rule out that the problem is with the control and not with the board.
- 05
The fuse on the PCB blows when turning on the boiler.
Cause: A fuse that blows immediately usually indicates a short circuit in the connected components, not necessarily on the PCB itself.
Before replacing it, disconnect the pump, gas valve, and fan one by one and check if the fuse holds without them.
Fault codes from Junkers that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| E0 | Internal fault in the PCB. | The Heatronic self-diagnosis detects an internal fault in the main PCB. First, check the power supply and connectors/bus; if the issue persists, measure low voltages on the board and replace the PCB. |
| F0 | Internal fault/PCB fault. | The main PCB shows an internal fault (hardware/firmware) or communication with the bus module. Check connectors, moisture in the Heatronic box, and wiring; if not resolved, replace the PCB or associated module. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Junkers 8748300158 PCB.
- Catalogue reference
- 8748300158
- Brand
- Junkers
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Safety module voltage (red block)
- 24 V
- Safety circuit fuse
- T1,6A
- Additional marking red module
- TO5A
- Reference (Junkers/Bosch)
- 8748300158
- The exact model published today by the store (Eurostar ZWE 24-2 ADE 23) does not appear as such in the verified list of compatible boilers; the closest one is ZWE24-2AE23.