PCB Junkers Cerastar/Euroline ZR-ZSR-ZWR-ZWE Ref. 8748300281

PCB Junkers Cerastar/Euroline ZR-ZSR-ZWR-ZWE Ref. 8748300281

The Junkers Cerastar/Euroline ZR-ZSR-ZWR-ZWE PCB is the component responsible for controlling the ignition, burner modulation, pump, and safety features of the boiler. When this part fails, the boiler may not start, become locked, or behave erratically, potentially displaying the fault code E9: STB activated. It is compatible with models such as ZR 18-3, ZR 24-3, ZSR 18-3, ZSR 24-3, ZWR 18-3, and ZWR 24-3, among others. A technician must confirm through diagnosis whether it needs to be replaced when the aforementioned symptoms occur to restore its operation.

Catalogue reference
8748300281
Warranty
1 year
VAT included OUT OF STOCK
Compatibility

Junkers boilers compatible with reference 8748300281

PCB with reference 8748300281. Seven confirmed compatibilities: ZR 18-3 and ZR 24-3.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZR 18-3Junkers Cerastar (ZR/ZSR/ZWR -3)Contrasted
Junkers ZR 24-3Junkers Cerastar (ZR/ZSR/ZWR -3)Contrasted
Junkers ZSR 18-3Junkers Cerastar (ZR/ZSR/ZWR -3)Contrasted
Junkers ZSR 24-3Junkers Cerastar (ZR/ZSR/ZWR -3)Contrasted
Junkers ZWR 18-3Junkers Cerastar (ZR/ZSR/ZWR -3)Contrasted
Junkers ZWR 24-3Junkers Cerastar (ZR/ZSR/ZWR -3)Contrasted
Junkers ZR 11-3Junkers Cerastar (ZR/ZSR/ZWR -3)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 8748300281 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 8748300281. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 8748300281

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not light up any indicators or respond to the control panel.

    Cause: The PCB does not distribute power to the control circuits.

    Measure with a multimeter if 230V is reaching the terminal block of the PCB and check the fuses T0.5A and T1.6A before replacing it.

  • 02

    One of the fuses blows again shortly after replacing it.

    Cause: It usually indicates a short circuit in the PCB itself, not a faulty fuse.

    Before replacing the fuse, disconnect the external components (pump, fan) one by one and check if it holds; if not, the fault is in the PCB.

  • 03

    The boiler ignites but shuts off after a few seconds with a lockout.

    Cause: The PCB does not properly process the flame or sensor signal and cuts off the gas supply for safety.

    Check that the connectors for the sensors and the electrode are properly seated in the terminal block before replacing the PCB.

  • 04

    The fault code on the display does not match any obvious fault in the other components.

    Cause: It may be due to an incorrect reading by the microcontroller on the PCB due to internal damage.

    Reset the boiler and note if the same code always reappears consistently; if it's erratic, it points more towards the PCB than an external component.

Junkers fault codes that require diagnosis

CodeFaultTechnical checks
E9STB activatedWhen you see "E9" on the display, it means that the STB (safety device) has been activated. If the PCB is not operational, it may not properly manage the signal from the NTC or the safety system. Check the NTC input, the operation of the pump, and the fuse on the printed circuit board.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers 8748300281 PCB.

Catalogue reference
8748300281
Uniclima internal SKU
PECZWR243
Brand
Junkers
Type of part
PCBs (control boards)
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Power supply (terminal block)
24 V
Fuse 1
T0.5A
Fuse 2
T1.6A
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 8748300281

Is this PCB suitable for the Junkers ZSR18-3?
Yes, it is among the compatible boilers along with ZR11-3, ZR18-3, ZR24-3, ZSR24-3, ZWR18-3, and ZWR24-3.
What electrical data can be seen on the PCB of the Junkers Cerastar/Euroline?
In the red terminal block: 24 V power supply and T0.5A and T1.6A fuses.
How many models are compatible with this PCB?
The Junkers Cerastar/Euroline PCB is compatible with a total of 7 models.
What fault code is documented for this PCB?
The documented fault code for this PCB is E9.
What is the reference for this PCB?
PECZWR243 is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.

Spare parts related to Junkers Junkers Cerastar (ZR/ZSR/ZWR -3)

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
PCB Junkers Cerastar/Euroline ZR-ZSR-ZWR-ZWE Ref. 8748300281