Main PCB Ariston Cares Premium 30 EU COD 3300760 Ref. 60002508 01

Main PCB Ariston Cares Premium 30 EU COD 3300760 Ref. 60002508 01

95 €VAT includedIn stock · 1 unit

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Compatible with Inoa Green 24 EU, Inoa Green 29 EU, Inoa Green 30 (ref. 60002508 01). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
60002508 01
Brand
Ariston
Type of part
PCBs (control boards)
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 60002508 01) equips these models. Verified compatibility; check the reference before purchasing.

Chaffoteaux Inoa Green

  • Inoa Green 24 EU
  • Inoa Green 29 EU
  • Inoa Green 30

Chaffoteaux CX Green

  • CX Green 24 EU
  • CX Green 29 EU

Ariston Cares Premium

  • Cares Premium 24 EU
  • Cares Premium 30 EU

Ariston HS Premium

  • HS Premium 24 EU
  • HS Premium 30 EU

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
3 03Main PCB faultSelf-diagnosis detects an internal fault in the main control board (PCB). Check 230 Vac and 2A fuse, connectors, and bus/display; if power supply and wiring are correct, replace the board.
3 05Main PCB faultThe main PCB reports an internal error (subcode 3 05). Check voltages, fuse, and connections; if there are no external anomalies, the cause is the PCB itself.
3 06Main PCB faultInternal fault detected in the PCB (subcode 3 06). Check power supply/wiring; if they are correct, confirm fault of the PCB with replacement/cross-test.
3 07Main PCB faultBoiler self-diagnosis indicates an internal error of the main PCB (subcode 3 07). Check 230 Vac network, 2A fuse, and connectors; if everything is correct, replace the PCB.
How do I know if this PCB is for my boiler?
Verify the reference 60002508 01 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.