Main PCB Biasi Myto Condens Plus 35 Ref. BI2445100

Main PCB Biasi Myto Condens Plus 35 Ref. BI2445100

85 €VAT includedIn stock · 1 unit

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks out, or the display is unresponsive. Compatible with RinNova Cond Plus 25, RinNova Cond Plus 30, RinNova Cond Plus 35 (ref. BI2445100). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
BI2445100
Brand
Biasi
Type of part
PCBs (control boards)
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. BI2445100) equips these models. Verified compatibility; check the reference before purchasing.

RinNova Cond Plus

  • RinNova Cond Plus 25
  • RinNova Cond Plus 30
  • RinNova Cond Plus 35

Myto Condens Plus (Biasi)

  • Myto Condens Plus 24

Platform M260V

  • M260V 2025SM

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
Er20EVG lockout (hardware fault).Fault in the EVG circuit on the main PCB (driver/relay/triac that controls the gas valve). Check by measuring the EVG output on the PCB during demand and ruling out wiring and gas valve.
Er21EVG lockout (hardware fault).Fault in the EVG channel on the PCB (e.g., relay/power stage for valve control). Check activation/continuity of the EVG relay on the board and ensure the valve receives a signal with the correct wiring.
Er22EVG lockout (hardware fault).Internal defect in the EVG electronics of the PCB causing anomalous detection and lockout. Verify EVG control signals on the PCB and rule out ionization/valving and wiring issues.
Er99Card not configured.Main PCB unparameterized after replacement or loss of configuration. Verify by entering programming mode and configuring the model (parameter P01/Pr01) according to the manual; after coding, the error should disappear.
How do I know if this PCB is for my boiler?
Verify the reference BI2445100 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Biasi part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.