Main PCB Fagor FE 24 AE 1N Ref. MU0500229
If your boiler does not start, locks up, or exhibits erratic behavior, a technical diagnosis must confirm whether you need the Main PCB Fagor FE 24 AE 1N, Ref. MU0500229 from P.M.A. This control board is responsible for managing the ignition, burner modulation, pump, and safety features of the boiler. If it fails, you may notice the fault code F5, which indicates an internal fault in the electronic circuit. It is compatible with several Fagor boiler models, such as the Super Compact ranges FE 24 E, FE 18 E, FE 27 E, among others. A technician must confirm through diagnosis whether it needs to be replaced when it shows operational failures or errors in its operation.
Fagor boilers compatible with reference MU0500229
PCB with reference MU0500229. 26 verified compatibilities: FE-24E/1 N and FE-24E/1 B.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE-24E/1 N | Fagor Super Compact FE 24 E | Contrasted |
| Fagor FE-24E/1 B | Fagor Super Compact FE 24 E | Contrasted |
| Fagor FE-24E H/1 N | Fagor Super Compact FE 24 E | Contrasted |
| Fagor FE24EC/1 N | Fagor Super Compact FE 24 E | Contrasted |
| Fagor FE24EC/1 B | Fagor Super Compact FE 24 E | Contrasted |
| Fagor FE 24 E UK-1 N | Fagor Super Compact FE 24 E | Contrasted |
| Fagor FE18E/1 N | Fagor Super Compact FE 18 E | Contrasted |
| Fagor FE18E/1 B | Fagor Super Compact FE 18 E | Contrasted |
| Fagor FE27E/1 N | Fagor Super Compact FE 27 E | Contrasted |
| Fagor FE27E/1 B | Fagor Super Compact FE 27 E | Contrasted |
| Fagor FE27ECN/1 N | Fagor Super Compact FE 27 E | Contrasted |
| Fagor FEB27EUK1N | Fagor Super Compact FE 27 E | Contrasted |
| Fagor FE30E/1 N | Fagor Super Compact FE 30 E | Contrasted |
| Fagor FE30E/1 B | Fagor Super Compact FE 30 E | Contrasted |
| Fagor CA24E N | Fagor CA / CE | Contrasted |
| Fagor CA24E B | Fagor CA / CE | Contrasted |
| Fagor CE-24E N | Fagor CA / CE | Contrasted |
| Fagor CE24E/1 B | Fagor CA / CE | Contrasted |
| Fagor CE30E/1 N | Fagor CA / CE | Contrasted |
| Fagor CE30E/1 B | Fagor CA / CE | Contrasted |
| Fagor FA23E N | Fagor FA / FEB 23-24 E | Contrasted |
| Fagor FA23E B | Fagor FA / FEB 23-24 E | Contrasted |
| Fagor FEB23E/1 N | Fagor FA / FEB 23-24 E | Contrasted |
| Fagor FEB23E/1 B | Fagor FA / FEB 23-24 E | Contrasted |
| Fagor FEB24E/1 N | Fagor FA / FEB 23-24 E | Contrasted |
| Fagor FEB24E/1 B | Fagor FA / FEB 23-24 E | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. MU0500229 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference MU0500229. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB MU0500229
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite, it doesn't even spark when heat is requested.
Cause: The ignition module is responsible for generating the spark; if it fails, the burner never starts.
Check that power is reaching the ignition electrodes and that the module cable is not loose or damaged before replacing the entire PCB.
- 02
The boiler locks out right when trying to start, almost without giving you time to see it.
Cause: A blown 6.3A fuse cuts off the power to the ignition circuit, and the PCB locks for safety.
Before replacing the PCB, measure the 6.3A fuse with a multimeter; if it's blown, replace it first and test again.
- 03
The boiler is completely dead, with no indicators or display.
Cause: If the fuse on the PCB has blown or the electronic control has completely failed, no power reaches any circuit.
Check the main fuse of the installation and the home's circuit breaker before assuming that the fault is in the boiler's PCB.
- 04
The boiler sometimes turns on and other times it locks out without any apparent reason.
Cause: An intermittent fault in the ignition module or in the control circuit causes irregular starts.
Note if the fault always occurs when cold or also when hot: it helps to distinguish a PCB problem from a pressure switch or sensor issue.
Fagor fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F5 | PCB fault (internal fault of the electronic circuit). | The main PCB enters a fault (software protections/relays/microcontroller), blocking the boiler; check service voltages on the PCB (5/12 V), connectors and run autotest; if it persists, replace the PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fagor MU0500229 PCB.
- Catalogue reference
- MU0500229
- Uniclima internal SKU
- PEPFE24AE1N
- Brand
- Fagor
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Fuse
- 6.3 A
- Ignition module manufacturer
- M.A.W.P.
- Ignition module code
- BLX-4ACU
- The red ignition module is branded P.M.A. and has the code BLX-4ACU; this identifies the module, not necessarily the manufacturer of the complete PCB.