Main PCB Immergas Victrix 26 kW 1 Ref. 036495

Main PCB Immergas Victrix 26 kW 1 Ref. 036495

75 €VAT includedIn stock · 3 units

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks out, or the display is unresponsive. Compatible with Victrix 24 KW, Victrix 24 KW Plus, Victrix 26 KW (ref. 036495). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
036495
Brand
Immergas
Type of part
PCBs (control boards)
Available units
3 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 036495) equips these models. Verified compatibility; check the reference before purchasing.

Victrix KW

  • Victrix 24 kW
  • Victrix 24 kW Plus
  • Victrix 26 kW
  • Victrix 26 kW Plus

Victrix Intra KW

  • Victrix Intra 24 kW
  • Victrix Intra 24 kW Plus
  • Victrix Intra 26 kW
  • Victrix Intra 26 kW Plus

Victrix Zeus KW

  • Victrix Zeus 26 kW
  • Victrix Zeus 26 ERP

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
E04Lockout due to generic anomaly of the boiler control board: the microprocessor incorrectly recognises a signal from the PCB.It is the code most directly attributable to the PCB itself: an internal fault or signal from the microprocessor on the board causes it. Check: after a reset, the lockout reappears immediately or recurrently without any peripheral component (sensors, fan) being faulty, which points to the PCB.
E80Lockout due to malfunction of the main PCB controlling the boiler.The boiler detects an abnormal operation of the PCB itself (not of an external component). Verify: persists after Reset and after ruling out gas valve/wiring; clear indication of an internal fault in the PCB.
E62Full calibration request: the PCB lacks combustion system calibration.It triggers after replacing the new PCB without calibration (the spare PCB arrives without air/gas parameters recorded). Verify: it appears right after installing this part; it is resolved with a full calibration from the service menu.
E72Quick calibration request: the board detects a change in parameters that requires recalibration.It is activated when the PCB is changed (change of air/gas parameters detected by the new PCB). Verify: it occurs after the replacement of this part; it is cleared by performing the quick calibration in the service menu.
How do I know if this PCB is for my boiler?
Verify the reference 036495 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a B&P (Bertelli & Partners) part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.