PCB Baxi Roca Victoria 24/24 F Ref. 125568739
The control PCB of the Baxi Roca Victoria 24/24 F manages the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, lock out, or behave erratically, displaying fault codes such as E99, E98, or E35. This part is compatible with several models in the Victoria range, including the Victoria 20/20 and the Victoria 24/24, among others. It is recommended to replace it when the mentioned symptoms or operational errors occur.
VAT included
Consult via WhatsAppBaxi Roca boilers compatible with reference 125568739
PCB with reference 125568739. Three confirmed compatibilities: Victoria 20/20 and Victoria 24/24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca Victoria 20/20 | Victoria | Contrasted |
| Baxi Roca Victoria 24/24 | Victoria | Contrasted |
| Baxi Roca Victoria 24/24 F | Victoria | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 125568739 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 125568739. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 125568739 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not turn on, there are no lights or display.
Cause: The PCB is not sending current to the rest of the electronics.
Check if the fuse on the PCB is blown before replacing it completely.
- 02
The remote control or the control panel do not respond, even though the boiler is on.
Cause: The PCB has lost communication with the control electronics.
Turn off the power to the boiler, wait a minute, and turn it back on to rule out a temporary fault before replacing the PCB.
- 03
The boiler turns on and off by itself intermittently, without a clear pattern.
Cause: A fault in the PCB causes erratic control of the ignition or safety.
Note whether the fault occurs when using domestic hot water, heating, or both, before deciding that it is the PCB.
- 04
An error code appears on the display that does not clear after resetting the boiler.
Cause: The PCB detects an internal or communication fault and keeps it locked.
Check the boiler manual to find out which component indicates that code before assuming it is the PCB.
- 05
The relay clicks but the boiler does not respond.
Cause: The relay works, but the output to the component has no effect.
With the boiler unplugged, check that the connectors on the PCB are properly fitted and free of rust before replacing it.
Fault codes for Baxi Roca that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| E99 | Communication fault between micros or PCB error | The PCB fails in its self-diagnosis/internal communication (between microcontrollers) or with managed elements; check polarity, grounding, and voltages, and if the issue persists, confirm communication lines or test with a known PCB. |
| E98 | Communication fault between micros or PCB error | The PCB shows an internal communication fault (parameters/EEPROM/firmware) that blocks the electronics; check power supply, grounding, and parameter settings after changing the PCB (e.g. F03/F12) and, if not corrected, replace or reprogram the PCB. |
| E35 | Parasite flame (flame error) | The flame detection stage in the PCB interprets spurious signals due to leaks/currents or a fault in the ionisation circuit; check the ionisation electrode and ground, moisture on the board, and if it persists, measure the signal and test/replace the PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Baxi Roca PCB 125568739
- Catalogue reference
- 125568739
- Brand
- Baxi Roca
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Transformer - secondary voltage
- 156.5 Vac
- Transformer - primary current/frequency
- 120 mA, 50/60 Hz
- Transformer - regulations
- BS7699
- OM 5.834