PCB Management Beretta Kompakt 24 CSI Ref. R10029773

PCB Management Beretta Kompakt 24 CSI Ref. R10029773

80 €VAT includedIn stock · 3 units

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks out, or the display is unresponsive. Compatible with Kompakt 24 CSI (AR), Kompakt 24 CAI (N), Exclusive 24 CAI (ref. R10029773). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
R10029773
Brand
Beretta
Type of part
PCBs (control boards)
Available units
3 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. R10029773) equips these models. Verified compatibility; check the reference before purchasing.

Kompakt

  • Kompakt 24 CSI (AR)
  • Kompakt 24 CAI (N)

Exclusive

  • Exclusive 24 CAI
  • Exclusive 28 CAI
  • Exclusive 28 RAI

Exclusive Microcai

  • Exclusive Microcai 24 CAI
  • Exclusive Microcai 28 CAI

Family (Riello)

  • Family 24 Ki
  • Family 28 Ki

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
51PCB (control board)Fault in the control board (PCB): hardware/firmware defect or internal communication. Check supply voltages on the board, connectors/grounds, and if it persists, reprogram or replace the PCB R10029773.
52PCB (control board)Anomaly attributed to the control board: possible damaged components or logical error. Check the power supply and regulators on the board, continuity of harnesses, and replace/parameterize the PCB if necessary.
53PCB (control board)PCB fault commonly linked to memory/EEPROM or parameter read/write. Verify memory integrity (reprogramming) and, if not recovered, replace the PCB.
54PCB (control board)PCB anomaly related to parameters/firmware. Check and restore service parameterization; if the fault persists after reprogramming, replace the PCB.
55PCB (control board)Generic fault in the control board detected by self-diagnosis. Check power supply, damaged tracks/components, and basic operation; replace PCB if it does not recover.
56PCB (control board)PCB anomaly that may involve modulation circuit/driver. Check modulation outputs, shorts to ground, and if the driver is damaged, replace the PCB.
57PCB (control board)Internal fault of the control board (self-diagnosis). Check service voltages and internal buses; if there is no recovery after reset/parameterization, replace the PCB.
58PCB (control board)Fault detected in logical circuits or input/output of the PCB. Check sensors/inputs and associated electronics on the PCB; replace the board if the fault persists.
59PCB (control board)Fault in the PCB confirmed by the boiler's own diagnosis. Measure power supply/grounds and check for physical damage; if not corrected, replace the PCB R10029773.
How do I know if this PCB is for my boiler?
Verify the reference R10029773 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Riello piece (PCB AB05B, Riello code 4366197; a supplier attributes it to Technosystem srl).
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.
Scroll to the top