Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.63EEPROM fault.The EEPROM memory of the main PCB is damaged/corrupted; if NTCs and wiring are correct, the cause is the PCB. Check voltages and, if it persists, reprogram/replace the PCB.
F.64Fault in the electronics / NTC.If the NTC sensors and their wiring do not present shorts or inversion, the fault is in the PCB electronics (measurement/processing stage). Check NTCs and continuity; if okay, replace the PCB.
F.65Fault: electronics temperature.The PCB detects overheating or its internal sensor/power stage is faulty. Check ventilation/temperature and dissipation; if everything is correct, the cause is the PCB.
F.67Fault: electronics/flame.The flame detection/control circuit on the PCB is not plausible or defective. Check the ionisation signal and grounding; if they are correct, replace the PCB.
F.70Invalid product code (DSN).After replacing the display and PCB without readjusting the DSN or with incorrect coding resistance, the PCB locks the equipment. Verify/adjust DSN and resistance; if not accepted, incorrect/defective PCB.
F.32Fault: fan.When the motor and wiring are fine, the fault may be with the PCB (multiple connector on PCB, output/driver, or PWM control). Check the power/signal from the PCB to the fan; if there is no correct output, replace the PCB.