PCB Immergas Victrix Maior TT 3 Ref. 027083

PCB Immergas Victrix Maior TT 3 Ref. 027083

90 €VAT included

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Compatible with Victrix TT 24, Victrix TT 28, Victrix TT 35 (ref. 027083). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
027083
Brand
Immergas
Type of part
PCBs (control boards)
Available units
0 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 027083) equips these models. Verified compatibility; check the reference before purchasing.

Immergas Victrix TT

  • Victrix TT 24
  • Victrix TT 28
  • Victrix TT 35

Immergas Victrix Maior TT

  • Victrix Maior TT 24
  • Victrix Maior TT 28
  • Victrix Maior TT 35

Immergas Victrix Zeus

  • Victrix Zeus 25

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
36IMG BUS communication dropThe control board/PCB may fail on the IMG bus (communication errors or damaged BUS driver). Check voltage/signal on the BUS, connectors, and continuity; if the area and wiring are OK, replace/test the PCB.
62Full calibration requestCalibration absence detected on the PCB (common after replacing the board). Check by entering the service menu and execute "full calibration"; if it does not complete or reappears, reprogram/replace the board.
72Quick calibration requestChange of parameters requiring recalibration of the electronic board. Confirm in service menu and perform "quick calibration"; if the warning persists, check/program the PCB.
80Lockout due to malfunction of the PCBThe PCB that controls the gas valve is malfunctioning (driver/output damaged). Check the power supply and signal to the valve; if the valve and wiring are correct, replace the PCB.
94Combustion anomalyThe combustion control may fail due to a defective PCB (in addition to gas/recirculation/valve). Check gas pressure, flue gases, and sensor/ionization; if everything is correct, the cause is the control electronics (PCB).
How do I know if this PCB is for my boiler?
Verify the reference 027083 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Bertelli & Partners piece.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.
Scroll to the top