Saunier Duval SYMSI 7.0 PCB · 0310144400P16 for Themafast F25 E H-MOD

Saunier Duval SYMSI 7.0 PCB · 0310144400P16 for Themafast F25 E H-MOD

To confirm: It is the control board of the boiler: it is responsible for ignition, modulation, safety, and temperature management. It is suspected if the boiler does not ignite or respond, restarts, or shows faults without a physical cause.

internal SKU
PLC106
Warranty
1 year
VAT included Stock · 2 units
Compatibility

SUNG WEI compatible boilers

PCB. Three confirmed compatibilities: Saunier Duval Themafast F25 E H-MOD and Saunier Duval Themaclassic F25E. There are another 5 models that we are still verifying.

Proven compatibility

Boiler modelFamilyVerification
SUNG WEI Saunier Duval Themafast F25 E H-MODSUNG WEIContrasted
SUNG WEI Saunier Duval Themaclassic F25ESUNG WEIContrasted
SUNG WEI F1LASUNG WEIContrasted

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

SUNG WEI Saunier Duval Themafast F 30 E H-MODSUNG WEIUnconfirmed
SUNG WEI Saunier Duval Themafast F 24 ESUNG WEIUnconfirmed
SUNG WEI Saunier Duval Themaclassic C 24 E, C 25 E, F 24 E and AS 24/25/30 ESUNG WEIUnconfirmed
SUNG WEI Saunier Duval Themafast F25E and F30ESUNG WEIUnconfirmed
SUNG WEI Saunier Duval Themafast C 25 ESUNG WEIUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Look for the silkscreen 0310144400P16 and the designation SYMSI7.0 (or SYMSI 7.0) in the circuit.
  2. To confirm: 0310144400N14 and 0310144400015 are other versions, not this one. 0310144400T01 appears alongside S10470 and does not connect to the P16.
  3. Count the relays and check their position and that of the connectors: under the same code there are different versions.
  4. Look at the model on your boiler's PCB. Confirmed: Themafast F25 E H-MOD, C 25 E, Themaclassic F25E and F1LA. Unconfirmed: Themafast F 24 E and F 30 E H-MOD.
  5. If they match, call us at 911 17 77 77 with the model of your boiler.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite or respond to any commands.

    Cause: it is associated with the SYMSI 7.0 PCB of the Themafast.

  • 02

    Errors on the screen without a physical cause or restarts in the middle of a heating cycle.

    Cause: According to that, they may come from the PCB.

  • 03

    Stuck relays, burnt tracks or oxidation in the circuit.

    Cause: They can be seen when looking at the PCB.

  • 04

    The boiler does not ignite or turns off during operation and does not ignite again (fault codes F28 or F29).

    Cause: Ignition fault: it may be due to lack of gas, gas meter, ignition or PCB.

    Put the boiler out of service, wait 5 seconds, and then restart it. If the issue persists, have it checked by the official SAT.

  • 05

    The red pilot light is flashing and a fault code F followed by a number appears on the screen: the boiler stops due to an anomaly.

    Cause: The PCB has detected an anomaly. The number indicates which one: ignition, flue, sensors, or circulation.

    Reset it: turn off the boiler, wait 5 seconds, and turn it back on. If the fault persists, have it checked by the official technical service.

Códigos de error SUNG WEI que requieren diagnóstico

CodeFaultTechnical checks
F28Ignition fault: the burner does not ignite.Put the boiler out of service, wait 5 seconds, and then restart it. If the issue persists, have the official SAT check it: it could be the gas or the ignition.
F29Ignition failure after losing the flame during operation.Just like the F28: put the boiler out of service, wait 5 seconds, and then restart it. If the issue persists, have it checked by the official service.
F15Flame detection fault: there is a flame with the burner off.If it occurs when turning off or on, have a technician check it: it points to the PCB or the flame control.
F5Fault of the heating flow sensor (NTC2).Check if the sensor connector is loose. If it persists, have a technician check it: it could be the sensor, the cable, or the PCB.
F1Ignition fault, possible gas supply issue (in Themafast C; in NOx it appears as F28 or F29).Put the boiler out of service, wait 5 seconds, and then restart it. If the issue persists, have a technician check it.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: SUNG WEI

Uniclima internal SKU
PLC106
Brand
SUNG WEI
Type of part
PCBs (control boards)
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer marking on PCB
SUNG WEI 06V0-A
Power/connection markings
ALIM 230V; TA 230V (silkscreen of the PCB)
Subcomponent: relay
OMRON G5LA-1A; DC24V coil
Part label identifier
0020021125
Source of additional data
Declared information; auxiliary references and applications without equivalent from the accredited manufacturer.
Inventory — Relay subcomponent
OMRON G5A-1A; DC24V coil
Inventory — Marked code
0020021125; 07/44; IND 5; S0080; SD00081C
Additional information — Power supply
230 V · 50 Hz · P16 V1
Additional information — Relays
4 (version P16 V1) ·
Registered reference
0310144400P16
Registered model
SYMSI7.0
Additional markings
OMRON G5A-1A relay, DC24V coil; also OMRON G5LA-1A, without assigned coil voltage. Connections ALIM 230V/TA 230V. Other codes: 0020021125; 07/44; IND 5; S0080; SD00081C.
Pending applications to verify
Saunier Duval THEMAFAST C 25 E — compatibility mentioned; pending verification by variant. Statements from (documentation 10/23/2026; revision 10/24/2026), pending confirmation by manufacturer. Check reference, revision, and serial number before use: Themafast F 24 E · Themafast F 25 E H-MOD · Themafast F 30 E H-Mod · Themafast F25E · Themafast F30E · Themafast F30E (2004)
Before purchasing
  • To confirm: Saunier Duval Themafast F 30 E H-MOD —, with the P16 (the list is the same for the 015), with S10470 or N14.
  • To confirm: Saunier Duval Themafast F 24 E — it is given with the P16 (and repeats the list for the 015). It also names "F 24 E" with the P16, but in a general list without family: it doesn't count. (S10470) and (N14), with other codes.
  • To confirm: Saunier Duval Themaclassic C 24 E, C 25 E, F 24 E and AS 24/25/30 E — with SYMSI 7.0:; gives S10470
  • To confirm: Saunier Duval Themafast F25E and F30E — with SYMSI 7.0: (P16) and (N14)
  • Do not confuse: 0310144400N14 — Another version SYMSI 7.0, which is compatible with Themafast F24 E, F25 E H-MOD and F30 E H-MOD — Different termination: compare relays and connectors.
  • Do not confuse: 0310144400015 — Version V4 with 3 relays (2+1), — It is not the P16: the P16 V1 has 4 relays.
  • 0020021125 and SD00081C come from the label of a unit; they are not mentioned.
  • and they join the P16 with the SYMSI 7.0 from Saunier Duval. Without official breakdown and with other versions (N14, 015): compare the code in the unconfirmed boilers.
  • Pending registered applications to confirm by model, variant, or programming: Saunier Duval Themafast C 25 E.
Frequently Asked Questions

Frequently asked questions about the PCB (control board)

How do I identify this PCB?
Look for the silkscreen 0310144400P16 and the designation SYMSI7.0 in the circuit: our three units have both. The Themafast C 25 E also has 0020021125 and SD00081C on the label.
Is it compatible with my Themafast F25 E H-MOD, Themafast C 25 E, Themaclassic F25E or F1LA?
Check the status of each model in the compatibility sections; the pending variants are not validated. To confirm: Yes. Registered: for those four boilers. It matches with the P16 for the F25 E H-MOD. It matches the F25 E H-MOD with the N14 and the Themaclassic F25E, the C 25 E and the F25 E H-MOD with the S10470, other references from the family. It mentions the Themaclassic F25E in SYMSI 7.0.
Is it compatible with the Themafast F 30 E H-MOD or the F 24 E?
Check the status of each model in the compatibility sections; the pending variants are not validated. They are not among the registered ones. F 30 E H-MOD: it is listed with the P16 (the same list for the 015), with S10470 or N14 (this warns that the F25 and F30 do not use the same parts). F 24 E: it is listed with the P16 and repeats the list for the 015; it is mentioned in a general list without a family. Compare the code of your PCB or send us a photo of the label from Contact (911 17 77 77).
What is the difference between the P16 and the N14, 015, or T01 endings?
N14 and 015 are different versions of the SYMSI 7.0. It states that the N14 suffix distinguishes variants and is given for the F25 E H-MOD, which Registered confirmation: with the P16. It lists the P16 V1 with 4 relays and the 0310144400015 V4 with 3 relays (2+1). The T01 only appears alongside S10470: without additional confirmation, it links it to the P16.
What do the codes on the PCB mean?
0310144400P16 is the printed circuit code and SYMSI7.0 is its designation. 0020021125 and SD00081C are listed on the unit label for the Themafast C 25 E; S10470 (also S1047000) is the catalog code for the SYMSI 7.0, which is not linked to the P16.
What symptoms point to this PCB and who should install it?
quote for the SYMSI 7.0 of the Themafast: boiler that does not ignite or does not respond, errors without physical cause, resets mid-cycle, and stuck relays or burnt tracks. It must be installed by a qualified technician: it operates at 230 V; it is recommended to disconnect the power supply and return each connector to its identical position.
How to identify this PCB?
Compare the silkscreen, the distribution of the connectors, and the exact variant of the circuit with the photographs.

Spare parts related to SUNG WEI SUNG WEI

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Saunier Duval SYMSI 7.0 PCB · 0310144400P16 for Themafast F25 E H-MOD