Saunier Duval Control PCB SD 235 ME Ref. 05710700

Saunier Duval Control PCB SD 235 ME Ref. 05710700

55 €VAT includedIn stock · 5 units

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks out, or the display is unresponsive. Reference 05710700. Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
05710700
Brand
Saunier Duval
Type of part
PCBs (control boards)
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.42Resistance fault coding (probably in combination with F.70)The PCB can cause F.42 if the coding resistor (gas type/power) integrated in the PCB fails or if, after replacing the PCB, the DSN has not been reprogrammed; verify by measuring the resistance on the PCB and adjusting the product code (e.g., d.93).
F.70Invalid product code (DSN)This appears when both the display and PCB are replaced simultaneously and the DSN is not reconfigured, or if the coding resistor on the PCB is incorrect; check the DSN reading and the coding resistor on the board, and reprogram according to the manual.
F.97Main PCB self-check faultThe internal self-test of the main PCB fails due to an electronic fault in the board; check power supply and connectors, and if it persists, replace the PCB.
F.64Electronic fault / NTCA short circuit/plausibility in NTC can be correct, but if the sensors and wiring are OK, the origin is the electronics of the PCB (analogue inputs/reference); check NTCs and, if they are within range, check/replace the PCB.
F.27Safety shutdown: incorrect flame detectionThe flame control electronics on the PCB can detect spurious flame due to moisture/leakage or a fault in the ionisation circuit on the board; check the electrode, grounding, and if they are correct, verify the detection stage on the PCB.
F.62Fault: gas valve control / delayed disconnectionThe valve driver/relay on the PCB may not cut off in time or may stick, causing a delay in closing; check voltage/timings on the valve and, if the valve assembly is correct, the cause is the electronics of the PCB.
F.61Error: gas valve controlThe PCB can cause F.61 due to a fault in the control circuit of the gas valve (driver/relay); check the wiring and coils of the valve, and if they are correct, replace the PCB.