Saunier Duval Isofast Condens F30E/F35E Electronic Module Ref. 0020204484
The Saunier Duval Isofast Condens F30E/F35E boiler includes the electronic module Ref. 0020204484, which acts as the control board responsible for managing the ignition, burner modulation, pump, and safety features. If this part fails, you will notice that the boiler does not start, locks out, or exhibits erratic operation. It is compatible with models from the Isofast Condens, Isomax Condens, and Isotwin Condens ranges, among others. It is recommended to replace the electronic module when faults such as F.63, F.64, or F.67 occur.
Saunier Duval boilers compatible with reference S1040000
PCB with reference S1040000. Four confirmed compatibilities: F 30 E and F 35 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 30 E | Isofast Condens | Contrasted |
| Saunier Duval F 35 E | Isofast Condens | Contrasted |
| Saunier Duval F 35 E | Isomax Condens | Contrasted |
| Saunier Duval F 30 E | Isotwin Condens | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1040000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1040000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB S1040000 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The fan does not start, or it starts and stops immediately, and the boiler locks out due to a combustion fault.
Cause: This module has the dedicated connector that controls the fan; if its control stage fails, the command or the correct speed does not reach the motor.
Before changing the module, check that the fan spins freely by hand with the boiler unplugged and that it does not make any bearing noise: if the motor is seized, the problem is the fan, not the PCB.
- 02
The circulation pump or the burner does not start when it should, although the boiler seems to receive the command.
Cause: The module incorporates two output relays, one rated at 8A/250VAC and the other at 24VDC, which supply power to these components; if one relay gets stuck or does not close, the component it controls will be left without command.
Check if the affected component works by forcing it in another mode of the boiler, to isolate whether the fault is in the relay of the module or in the component itself.
- 03
The boiler is locking out with a fault code related to the fan or flue gas evacuation.
Cause: The module interprets the fan speed signal and determines if there is sufficient airflow; a fault at this stage generates safety lockouts even if the fan is functioning properly.
Check that the flue duct is not blocked and that the connector marked "Fan" is properly seated, with no bent pins, before replacing the module.
- 04
General fault: the boiler stops responding completely, with no ignition or display.
Cause: A global fault in the control module leaves all components that depend on it without control.
Check the fuse of the module and the main power supply of the boiler before considering it dead: a blown fuse gives the same symptom and is much cheaper.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.70 | Invalid product code (DSN). | Joint replacement of screen and PCB (S1040000) without reprogramming the DSN or incorrect power/gas coding resistor on the PCB; check in service menu (e.g., d.93), review/code resistor and recode DSN. |
| F.63 | EEPROM fault. | Memory/electronic fault in the PCB (S1040000); confirm after reset and checking voltages/grounds; if it persists, reprogram or replace the PCB. |
| F.64 | Fault in the electronics / NTC. | The analog front-end/ADC of the PCB detects a short circuit/impossible readings from the NTC or is faulty; isolate by disconnecting/measuring the NTC and wiring, and if they are correct, replace the PCB. |
| F.65 | Fault: electronics temperature. | Overheating of the PCB; check for external heat sources/ventilation and actual temperature on electronics; if it reappears without an external cause, replace the PCB. |
| F.67 | Fault: electronics/flame. | The flame control ASIC on the PCB delivers an implausible signal; measure ionisation current and ground, and if they are correct, the electronics (S1040000) are faulty. |
| F.42 | Resistance fault coded (probably in combination with F.70). | Gas type coding resistor on the PCB short-circuited/open or incorrectly coded; check value and connections (and those of the power harness) and recode/replace the board if the integrated resistor fails. |
| F.27 | Safety shutdown: incorrect flame detection. | Moisture/damage in the flame control electronics of the PCB causes out-of-phase flame detection; inspect/retighten seals, dry and check the board and ionization signal before replacing it. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S1040000 PCB.
- Catalogue reference
- S1040000
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 0 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Label code (more prominent)
- 0020204484 (along with 92730077R / 665 / 233_07_01)
- Secondary code on label
- 0222104464
- Marking of the PCB
- BMU_02
- Output relays
- 2x ZETTLER relay: one of 8A 250VAC and another model AJ3030 of 24VDC
- Relay marking on X19
- 0020204604
- Connectors of the PCB
- X10 | X11 Fan | X19 Opt | X20