Vaillant PCB VMW 232-1
The Vaillant VMW 232-1 PCB (control board), reference S1047000, is a component that controls the ignition, burner modulation, pump, and safety features of the boiler. When it malfunctions, the boiler may fail to start, become locked, or operate erratically. This board is compatible with models from the Turbocombi range VMW 232-1, such as the VMW 232/1 and VMW2321, among others. It is recommended to replace it when symptoms of malfunction are detected, such as fault codes F.61, F.62, F.63, F.64, or F.67.
VAT included
Consult via WhatsAppVaillant boilers compatible with reference 130835
PCB with reference 130835. Three confirmed compatibilities: VMW 232-1 and VMW 232/1.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Vaillant VMW 232-1 | Turbocombi VMW 232-1 | Contrasted |
| Vaillant VMW 232/1 | Turbocombi VMW 232-1 | Contrasted |
| Vaillant VMW2321 | Turbocombi VMW 232-1 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 130835 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 130835. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 130835 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler is completely off, not even the ignition light is on.
Cause: There is a fault in the power supply to the PCB.
Check if there is power to the PCB and verify that there are no blown fuses before replacing it.
- 02
The fault indicator is flashing and the boiler won't start.
Cause: The PCB has blocked the cycle due to a safety anomaly.
Count the blinks or check the fault code if there is one, and compare it with the fault table before replacing the PCB.
- 03
The flame ignites but goes out immediately for no apparent reason.
Cause: The PCB does not maintain the ionization signal properly or controls the gas valve poorly.
Check that the ignition and ionization cables are properly connected to the PCB before replacing it.
- 04
The temperature controls do nothing, the boiler does not respond to them.
Cause: The control section of the PCB does not process user commands.
If you can, try another thermostat to rule out that the fault comes from outside the PCB.
Fault codes from Vaillant that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.61 | Error: gas valve control | The PCB may not switch or correctly read the activation signal of the valve (relay/power stage or damaged track), causing an actuation fault. Check the voltage at the valve terminals during start-up and continuity/current from the control board; if the valve and wiring are OK, suspect the PCB. |
| F.62 | Error: gas valve disconnection controller | If the output stage of the PCB gets "stuck" or delayed, it keeps the gas valve energized after the flame extinguishes, causing the disconnection delay. Check with diagnostics the de-energization time and if there is any residual power to the valve; if the valve closes properly, the cause is usually in the PCB. |
| F.63 | Fault: EEPROM | Corruption or fault in the memory circuit on the PCB; the control locks the equipment. Check power supplies and grounds; if the fault persists after reset/parameterization, replace the PCB. |
| F.64 | Fault: PCB / sensor / analog to digital transformer | A/D reading fault or PCB electronics interpreting short circuits in NTC/inputs. Check NTCs and wiring; if sensors and 5V reference are correct, the fault is in the PCB. |
| F.67 | Electronic/flame fault (implausible flame signal) | The flame control electronics (ASIC/ionization stage on the PCB) interprets an implausible signal. Check the ionization electrode/cable and grounding; if they are correct, check the signal at the PCB terminals and replace the PCB if the processing fails. |
| F.70 | Invalid product code (DSN) | After replacing the display and/or PCB without reconfiguring DSN or with incorrect coding resistance on the board, the unit locks. Verify/adjust DSN in D.93/D.97 and check the coding resistance on the PCB. |
| F.97 | Main PCB self-test failed | The main board's self-test detects an internal fault in the PCB. Check power supply, fuses, and grounding; if it reappears, replace the PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Vaillant 130835 PCB.
- Catalogue reference
- 130835
- Brand
- Vaillant
- Type of part
- PCBs (control boards)
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Silkscreen code on the PCB
- DISLIN1
- Code/version on component label
- 4691 V.005