Vaillant PCB 735077 · 00712248 / 00712189 · VMW 24/282/2-5 and VMW 28/362-5-13
Vaillant PCB, circuit 735077. Compatibility confirmed for Vaillant VMW 24/282/2-5 and VMW 28/362-5-13; it includes relay, fuse, and 230 V connections. The fault observation remains after water ingress in the 230 V connector; it does not independently indicate a fault in the PCB.
- Type of part
- Vaillant
- Status
- Refurbished
- internal SKU
- PLC187
- Warranty
- 1 year
Compatible Vaillant boilers
Vaillant. Two confirmed compatibilities: Vaillant VMW 24/282/2-5 and Vaillant VMW 28/362-5-13. There are 2 other models that we are still verifying.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Vaillant VMW 24/282/2-5 | Vaillant | Contrasted |
| Vaillant VMW 28/362-5-13 | Vaillant | Contrasted |
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Vaillant VMW ES 282/3-5 | Vaillant | Unconfirmed |
|---|---|---|
| Vaillant Turbomax Plus 828E VUW 282/2-5 | Vaillant | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the printed code 735077 and the revision V084-B (on one unit it reads V084_B), next to PM-02 or PM-03.
- Look at the label: our units have 00712248 (04 00712248 008) or 00712189 (03 00712189 008). Compare that code as well as the circuit.
- To confirm: Do not consider 0020034604 equivalent, as for the Turbomax Plus VUW 282/2-5, the gasket is 735077.
- Check the exact model of your boiler on its rating plate: VMW 24/282/2-5 and VMW 28/362-5-13 are confirmed.
- If they match, call us at 911 17 77 77 with the model of your boiler.
Symptoms that require diagnosis in the Vaillant.
Common symptoms and faults
- 01
The Vaillant 735077 PCB stops functioning after water enters the 230 V connector, with nothing burned or oxidized visible at first glance (case of a wire, 2015).
Cause: Check for moisture or water residue in the 230 V connector before considering the PCB (control board) as good.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Vaillant
- Uniclima internal SKU
- PLC187
- Brand
- Vaillant
- Type of part
- Vaillant
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Fuse F1
- T2
- Terminal block
- 21V;230V
- Inventory — Screen-printed code of PCB
- 735077; visible revision/version: V084-B
- Inventory — Label code
- 03 00712189 008 010923 0
- Inventory — Markings from another CI
- Elmos; Vaillant
- Inventory — Mounted transformer
- 230 V~ 50–60 Hz
- Inventory — Other PCB markings
- TL-AB/77, TM-AB, TC-AB, BK-AB, BC-AB
- Inventory — Application indicated in inventory
- VMW 28/362-5-13
- Identification — Marked designation
- V084_B / PM-02
- Identification — Marked code
- 735077
- Identification — Marked code
- TM-AB TC-AB TL-AB/77
- Identification — Marked code
- 735141 /02
- Identification — Marked code
- 734498
- Fusible F1
- T2
- Bornera
- 21V;230V
- Inventory data — Screen-printed code of PCB
- 735077; visible revision/version: V084-B
- Inventory data — Label code
- 03 00712189 008 010923 0
- Inventory data — Markings from another CI
- Elmos; Vaillant
- Inventory data — Mounted transformer
- 230 V~ 50–60 Hz
- Inventory data — Other PCB markings
- TL-AB/77, TM-AB, TC-AB, BK-AB, BC-AB
- Inventory data — Application indicated in inventory
- VMW 28/362-5-13
- It is a single forum case, without boiler model or technical response: it serves as a notice, not as a diagnosis.
- To confirm: Vaillant VMW ES 282/3-5: (PCB 00712248 in the title)
- Vaillant Turbomax Plus 828E VUW 282/2-5: (technical sheet: PCB 735077); with 0020034604
- Do not confuse: 0020034604 — Vaillant PCB that British suppliers provide for the Turbomax Plus VUW 282/2-5. It is listed alongside 735077 («PCB 0020034604 was 130827 735077»). The distributor lists it as the PCB for the VMW 24/282-5 (R1 and R2), the VMW 28/362-5 (and R3), and the VMW 282/2-5: names similar to those of our boilers, not identical, and without mentioning 735077 or 00712248 — Only connects it to 735077 and its sheet mixes models: to be confirmed. Do not consider it equivalent without comparing the label. The confirmed boilers do not change.
- The two units share the circuit 735077 (V084-B) but have different labels (00712248 and 00712189): compare the label, not just the circuit.
- To confirm: The 735077 appears as a Vaillant PCB in () and the 00712248 in 1. Neither mentions the workshop boilers by their exact name. The 0020034604 only links it to the 735077.