Vaillant PM-02 PCB · 734766 · 00712027 for VMW ES 242 2-5 R3
Vaillant PM-02 PCB, circuit 734766 and reference 00712027, with registered compatibility for VMW ES 242 2-5 R3, ETN-AE, TC-AE and TL-AE/66. It includes a transformer, relays, and 230 V terminals. Erratic errors, sudden restarts, stuck relays, or burnt tracks require diagnosis; they do not identify the fault on their own.
- Type of part
- Vaillant
- Status
- Refurbished
- internal SKU
- PLC197
- Warranty
- 1 year
Compatible Vaillant boilers
Vaillant. Four confirmed compatibilities: Vaillant VMW ES 242 2-5 R3 and Vaillant ETN-AE. There are another 5 models that we are still verifying.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Vaillant VMW ES 242 2-5 R3 | Vaillant | Contrasted |
| Vaillant ETN-AE | Vaillant | Contrasted |
| Vaillant TC-AE | Vaillant | Contrasted |
| Vaillant TL-AE/66 | Vaillant | Contrasted |
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Vaillant VMW 24/282-5 R1 | Vaillant | Unconfirmed |
|---|---|---|
| Vaillant VMI 280-7 | Vaillant | Unconfirmed |
| Vaillant VMI 320-7 | Vaillant | Unconfirmed |
| Vaillant VMW 282/2-5 R1 | Vaillant | Unconfirmed |
| Vaillant Turbomax Plus 824E / 828E | Vaillant | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Check the printed circuit board of your PCB: it should be marked with 734766, V064E, and model PM-02.
- Look for the label with 00712027 and compare it; TC-AE and TL-AE/66 are also marked on the plate.
- In the breakdown of the VMW 242/2-5 R3, code 0020034604 is listed as the support for the PCB. It is not on the label of this board: always compare 734766 and 00712027.
- If they match, call us at 911 17 77 77 with your boiler model and we will reserve it for you.
Symptoms that require diagnosis in the Vaillant.
Common symptoms and faults
- 01
Erratic fault codes on the display without apparent cause.
Cause: To be confirmed: for the PCB 00712027.
- 02
Sudden resets during daily operation.
Cause: It is another symptom that is attributed to the PCB.
- 03
Stuck relays or burnt traces on the PCB.
Cause: They are visible at first glance: check the condition of the relays and the traces.
- 04
The boiler does not ignite or respond to any commands from the control panel.
Cause: for the PCB 00712027 (VMI 280-7). First, check that there is voltage reaching the board.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Vaillant
- Uniclima internal SKU
- PLC197
- Brand
- Vaillant
- Type of part
- Vaillant
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Terminal silkscreen
- 21V; 230V~; 7; 8; 9; L; N; 3; 4; 5
- Inventory — Indicated reference
- 00712027
- Inventory — Mounted relay
- E37/46/13; marked 734537
- Inventory — Upper burner
- 21 V and 230 V
- Inventory — Integrated circuit
- Elmos 4110C; marked 734498, 342A, 4230C
- Inventory — ZETTLER AZ761-1C-16DS(341) Relays
- 10 A, 250 VAC
- Inventory — Connection block
- 230 V; terminals L and N
- Inventory — Visible markings on PCB
- BM-AE and BC-AE
- Inventory — Application indicated in inventory
- VMW ES 242 2-5 R3 ETN-AE
- Inventory — Marked code
- 734766; TC-AE; TL-AE/66; PM-02; 04; 00712027; 009; 083450 7; 734537; E37/46/13
- Fuses from the control box (VMW 242/2-5 R3) — Fuse
- 2.0 A T2H · ref. 0020067507 · VMW 242/2-5 R3 spare parts
- Fuses from the control box (VMW 242/2-5 R3) — Fuse
- 1.25 AT · ref. 251961 · VMW 242/2-5 R3 breakdown
- Identification — Marked designation
- V064_E TM-AE
- Identification — Marked code
- 734766; TC-AE; TL-AE/66; PM-02
- Identification — Marked code
- 734537; E37/46/13
- Technical sheet: Terminal screen printing
- 21V; 230V~; 7; 8; 9; L; N; 3; 4; 5
- Inventory data — Indicated reference
- 00712027
- Inventory data — Mounted relay
- E37/46/13; marked 734537
- Inventory data — Upper burner
- 21 V and 230 V
- Inventory data — Integrated circuit
- Elmos 4110C; marked 734498, 342A, 4230C
- Inventory data — ZETTLER AZ761-1C-16DS(341) relays
- 10 A, 250 VAC
- Inventory data — Connection block
- 230 V; terminals L and N
- Inventory data — Visible markings on PCB
- BM-AE and BC-AE
- Inventory data — Application indicated in inventory
- VMW ES 242 2-5 R3
- Inventory data — Application indicated in inventory
- ETN-AE
- Inventory data — Marked code
- 734766; TC-AE; TL-AE/66; PM-02; 04; 00712027; 009; 083450 7; 734537; E37/46/13
- Registered model
- PM-02
- To confirm: These symptoms come from the commercial text, not from a technical document: they are not enough to declare the PCB faulty.
- To confirm: Vaillant VMW 24/282-5 R1 — : (00712027)
- To confirm: Vaillant VMI 280-7: and of (00712027)
- To confirm: Vaillant VMI 320-7 — : (00712027)
- To confirm: Vaillant VMW 282/2-5 R1 — : (00712027)
- To confirm: Vaillant Turbomax Plus 824E / 828E — with 734766 (B2B). 130806, which links to 734766, is listed as PCB for Turbomax Plus in the Vaillant catalog and others, without 734766.
- Do not confuse: 0020034604 — "PCB support" in the breakdown of the VMW 242/2-5 R3 (pos. 11, control box) — It does not appear on the label of this PCB. as a board (families VUW and VU, and a technical sheet of VMW 242/2-5 R3), but none mention 734766 or 00712027.
- Not confirmed: 734766 and 00712027: are marked on the same PCB. The spare parts catalog of Vaillant (840038.02) lists 130806 as the PCB for the VUW 242/2-5 and 282/2-5 (Turbomax Plus), without mentioning 734766. B2B links 130806 and 734766.
- To confirm: they provide 00712027 as the PCB and one 734766, without joining them. Discrepancy: the breakdown of the VMW 242/2-5 R3 lists 0020034604 as the circuit support, but as a PCB; two link it to the previous code 130806, PCB of Turbomax Plus in the Vaillant catalog.