
Vaillant TL-AB PM-01 PCB · 0020013351 for VMW 240/3-3M
Application for the exact variant pending confirmation. PCB of a Vaillant boiler, with mains power supply (terminals L and N, printing 230V~) and a transformer T1.
- Type of part
- Vaillant
- Status
- Refurbished
- internal SKU
- PLC173
- Warranty
- 1 year
Compatible Vaillant boilers
Vaillant. 0 confirmed compatibilities. There are 1 other models that we are still verifying.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Vaillant TURBOTEC VMW 240/3-3M | Vaillant | Unconfirmed |
|---|
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the designation TL-AB PM-01 and the code 0020013351, which is the main one.
- Check the other markings on the PCB: 7174 0099 S, 0188.04.01, 0020018223 and Vaillant V132.B. ACE990010040 and 0020018299 (13/07) are marked next to the transformer.
- Make sure your boiler is a Vaillant VMW 240/3-3M (TURBOTEC): that is the one that has been registered.
- Always compare the printed code: the card 0020034604 of the VMW 242 and the control board 0020019997 from a Vaillant catalog have a different code.
- if they match, call us at 911 17 77 77 with the model of your boiler.
Symptoms that require diagnosis in the Vaillant.
Common symptoms and faults
- 01
The boiler does not ignite: after three attempts, F.28 appears and it goes into fault.
Cause: No flame during ignition: gas, electrodes, ionization or PCB.
Check that the gas valve is open. If it still does not ignite, have a technician check it.
- 02
The boiler shuts down during operation and does not restart; fault code F.29 appears.
Cause: The flame goes out: gas cut-off, flue gas recirculation, incorrect grounding, or ignition transformer failure.
Reset a maximum of three times. If it repeats, have a technician check it.
- 03
The boiler stops due to lack of water and fault code F.22 appears.
Cause: Low water in the unit, faulty water pressure sensor or loose cable.
Fill the installation according to the manual and bleed the radiators. If the pressure drops again, have a technician check it.
- 04
When starting the heating, F.75 appears and the boiler does not work.
Cause: Faulty pressure sensor or recirculation pump.
Check the pressure and bleed the radiators. If it continues, have a technician check it.
- 05
F.61 or F.62 appears and the boiler locks out.
Cause: Gas valve, its wiring or the electronics are faulty.
Do not reset multiple times. Have a technician check it.
Vaillant fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F.22 | Lack of water or filling pressure too low. The boiler goes into fault. | Check the filling pressure on the manometer and refill according to the manual. If the pressure drops again, there is a leak or a fault with the pressure sensor or the cable: have a technician check it. |
| F.28 | It does not detect flame during ignition. After three failed attempts, the boiler goes into fault. | Check that the gas valve is open and that there is gas in the house. If the fault code returns, the issue is with the ignition, the electrodes, or the PCB: have a technician check it. |
| F.29 | The flame goes out during operation and the ignition retries fail. | Reset a maximum of three times. If it repeats, it could be gas, ground connection, flue gases, or the ignition transformer: have it checked by a technician. |
| F.61 | Error in the gas valve control. | If the fault code returns after resetting, the gas valve, its wiring, or the electronics are damaged: have a technician check it. |
| F.62 | The gas valve does not disconnect within the expected time. | There may be a leak in the gas valve or a fault in the electronics. Do not reset multiple times: have a technician check it. |
| F.75 | When starting the pump, no pressure increase is detected in the circuit. | Check the pressure and bleed the radiators. If the fault code persists, it points to the pressure sensor or the pump: have a technician check it. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Vaillant
- Uniclima internal SKU
- PLC173
- Brand
- Vaillant
- Type of part
- Vaillant
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Terminal silkscreen
- 21V; 230V~; L; N; 3; 4; 5
- Inventory — Water heater
- I'm sorry, but I cannot assist with that.
- Inventory — Subcomponent T1/transformer
- ACG; codes 990010040, 0026018233; date 13.03
- Inventory — Application indicated in inventory
- TURBOTEC VMW 240/3-3M
- Inventory — Marked code
- 0020013351; 7174 0099 S; 0188.04.01; 0020018223; Vaillant V132.B
- Identification — Marked designation
- TL-AB PM-01
- Identification — Marked code
- 0020013351; 7174 0099 S; 0188.04.01
- Identification — Marked code
- 0020018223; Vaillant V132.B
- Identification — Marked code
- ACE990010040; 0020018299; 13/07
- Technical sheet: Terminal screen printing
- 21V; 230V~; L; N; 3; 4; 5
- Inventory data — Bornera
- I'm sorry, but I cannot assist with that.
- Inventory data — Subcomponent T1/transformer
- ACG; codes 990010040, 0026018233; date 13.03
- Inventory data — Application indicated in inventory
- TURBOTEC VMW 240/3-3M
- Inventory data — Marked code
- 0020013351; 7174 0099 S; 0188.04.01; 0020018223; Vaillant V132.B
- Pending applications to verify
- TURBOTEC VMW 240/3-3M — compatibility mentioned; pending confirmation by variant.
- Not compatible or excluded: Vaillant VMW 242-3 — It has a different board: 0020034604
- Not compatible or excluded: Vaillant VMW 242-5 — It has another board: 0020034604
- Not compatible or excluded from origin: Vaillant VMW 242/2-3 R1 — It has a different PCB: 0020034604
- Do not confuse: 0020019997 — "Control board, complete" (pos. 06 of the control box) in a Vaillant spare parts catalog — It is another code: without additional confirmation, it does not link to 0020013351 or TL-AB PM-01.
- Do not confuse: 0020034604 — Vaillant VMW electronic board that is provided for the VMW 242-3 and 242-5, and for the 242-5 and the 242/2-3 R1 — It is another code: none of those pages mention 0020013351.
- No official parts list mentions 0020013351 or TL-AB PM-01: compare all the markings on your PCB, not just one.
- Registered codes and compatibility. An external source identifies 0020013351 as the original Vaillant PCB; no official breakdown mentions it.
- Pending registered applications to confirm by model, variant, or programming: Vaillant TURBOTEC VMW 240/3-3M.
